Chapter 11: Event Logs and the Syslog Client
214
Section II: Advanced Operations
For example, selecting LOCAL2 as the facility level assigns the
numerical code of 18 to all events sent by the switch to the syslog
server.
13. To include events of a selected severity, type
6
to select Event
Severity.
The following prompt is displayed:
Enter Severity levels to display (ALL, E - Error, W -
Warning, I - Information, D - Debug) ->
The possible options are:
ALL
All messages of the following types are displayed. This is the default.
E - Error
Only error messages are displayed. Error messages indicate that the
switch operation is severely impaired.
W - Warning
Only warning messages are displayed. These messages indicate that
an issue may require manager attention.
I
- Information
Only informational messages are displayed. Informational messages
display useful information that you can ignore during normal operation.
D - Debug
Debug messages provide detailed high-volume information that is
intended only for technical support personnel.
You can select more than one severity at a time, separated by a
comma, for example, E,W.
14. To send events generated by a particular AT-S63 software module,
type
7
to select Event Module.
The list of modules is displayed, as shown in Table 1, “AT-S63
Modules” on page 201. The default is All.
20
LOCAL4
21
LOCAL5
22
LOCAL6
23
LOCAL7
Table 4. Numerical Code and Facility Level Mappings (Continued)
Numerical
Code
Facility Level Setting
Содержание AT-9400
Страница 16: ...Figures 16 ...
Страница 18: ...Tables 18 ...
Страница 28: ...Preface 28 ...
Страница 30: ...30 Section I Basic Operations ...
Страница 60: ...Chapter 1 Basic Switch Parameters 60 Section I Basic Operations ...
Страница 64: ...Chapter 2 Port Parameters 64 Section I Basic Operations Port Type The port type ...
Страница 84: ...Chapter 2 Port Parameters 84 Section I Basic Operations ...
Страница 124: ...Chapter 6 Static Port Trunks 124 Section I Basic Operations ...
Страница 144: ...144 Section II Advanced Operations ...
Страница 196: ...Chapter 10 File Downloads and Uploads 196 Section II Advanced Operations ...
Страница 218: ...Chapter 11 Event Logs and the Syslog Client 218 Section II Advanced Operations ...
Страница 242: ...Chapter 13 Access Control Lists 242 Section II Advanced Operations ...
Страница 294: ...294 Section III IGMP Snooping MLD Snooping and RRP Snooping ...
Страница 314: ...Chapter 19 MLD Snooping 314 Section III IGMP Snooping MLD Snooping and RRP Snooping ...
Страница 318: ...318 Section IV SNMPv3 ...
Страница 416: ...Chapter 21 SNMPv3 416 Section IV SNMPv3 ...
Страница 418: ...418 Section V Spanning Tree Protocols ...
Страница 470: ...470 Section VI Virtual LANs ...
Страница 478: ...Chapter 24 Port based and Tagged VLANs 478 Section VI Virtual LANs The new Sales VLAN has now been created ...
Страница 480: ...Chapter 24 Port based and Tagged VLANs 480 Section VI Virtual LANs The new Engineering VLAN has now been created ...
Страница 520: ...Chapter 26 Multiple VLAN Modes 520 Section VI Virtual LANs ...
Страница 532: ...Chapter 27 Protected Ports VLANs 532 Section VI Virtual LANs ...
Страница 546: ...546 Section VII Internet Protocol Routing ...
Страница 560: ...560 Section VIII Port Security ...
Страница 568: ...Chapter 30 MAC Address based Port Security 568 Section VIII Port Security ...
Страница 586: ...Chapter 31 802 1x Port based Network Access Control 586 Section VIII Port Security ...
Страница 588: ...588 Section IX Management Security ...
Страница 610: ...Chapter 33 Encryption Keys 610 Section IX Management Security ...
Страница 650: ...Chapter 36 TACACS and RADIUS Protocols 650 Section IX Management Security ...
Страница 660: ...Chapter 37 Management Access Control List 660 Section IX Management Security ...
Страница 668: ...Index 668 ...