Figure 2: DC Power inlet terminals on an AT-8724XL.

The Fault LED should flash for approximately 10 seconds as the switch 
runs internal tests. If the LED continues to flash or remains lit, refer to the

 

AT-8700XL Series Hardware Reference

 for troubleshooting information.

10. Check that the Power LED on the switch’s front panel lights green

If the LED fails to light, refer to the

 AT-8700XL Series Hardware Reference

 for 

troubleshooting information.

11. Connect the Redundant Power Supply (Optional)

AC models of AT-8700XL Series switches have a Redundant Power Supply 
(RPS) connector on their rear panel.

The switch is designed to operate with the AT-RPS8000 RPS, which can be 
purchased separately. Contact your authorised Allied Telesyn distributer 
or reseller for more information.

12. Connect the data cables

Make sure each cable connection is secure. The switch will now perform 
basic Layer 2 switching functions.

Configuring the Switch

Some configuration is necessary if you wish to enable the switch’s advanced 
switching capabilities. The switch can be configured via the Command Line 
Interface (CLI) or Graphical User Interface (GUI).

Using the CLI to configure a switch

1.

Connect a terminal or PC to the Terminal Port (ASYN0)

Using the supplied RS-232 DB9 straight-through cable, connect your 
terminal or PC to the RS-232 Terminal Port on the switch’s front panel.

2.

Set the communication parameters

Set the communication parameters on your terminal or terminal emulation 
program to:

Baud rate: 9600

Data bits: 8

Parity:  None

Stop bits: 1

Flow control: Hardware

38-75VDC      , 2A

FOR CENTRALIZED DC 
POWER CONNECTION, 

INSTALL ONLY IN A 

RESTRICTED AREA

DC Power inlet

DC    INPUT

Содержание AT-8724XL

Страница 1: ...AT 8700XL Series Switch Quick Install Guide AT 8724XL AT 8748XL ...

Страница 2: ...ke changes in specifications and other information contained in this document without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesyn be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information containe...

Страница 3: ... only One serial cable for connecting the switch to a terminal or PC One 19 inch rack mount kit One AT 8700XL Series Quick Install Guide One Safety and Statutory Information booklet One AT 8700XL Series Documentation and Tools CD ROM which includes the complete AT 8700XL Series Document Set and utilities One warranty card AT 8700XL Series Printed Acrobat PDF Website Documentation Roadmap AT 8700XL...

Страница 4: ...ng maximum cable length limitations See the AT 8700XL Series Hardware Reference for cable length specifications Installing the Switch All AC and DC versions of this equipment must be earthed Follow these steps to install the switch 1 Before installing the switch read the safety information For safety information see the Safety and Statutory Information booklet A copy of this booklet is supplied wi...

Страница 5: ... operate or damage to the switch may result 8 Apply AC power to the switch for AC models Plug the power cord into the AC power connector on the switch s rear panel The Fault LED should flash for approximately 10 seconds as the switch runs internal tests If the LED continues to flash or remains lit refer to the AT 8700XL Series Hardware Reference for troubleshooting information Figure 1 AT 8724XL f...

Страница 6: ... negative grounded Circuit protection Use a 10 Amp circuit breaker To connect the DC supply a Ensure the supply cable is not live b Strip the supply cable wires to expose 8mm 0 31 in of bare conductor c At the switch connect the ground wire to the ground terminal terminals can be identified by the diagram on the switch s rear panel see Figure 2 Tighten the terminal to between 0 6 0 8 Nm 0 041 0 05...

Страница 7: ...uthorised Allied Telesyn distributer or reseller for more information 12 Connect the data cables Make sure each cable connection is secure The switch will now perform basic Layer 2 switching functions Configuring the Switch Some configuration is necessary if you wish to enable the switch s advanced switching capabilities The switch can be configured via the Command Line Interface CLI or Graphical ...

Страница 8: ...p files To display a list of help topics enter help To display help on a specific topic enter help topic Alternatively type a question mark at the end of a partially completed command to see a list of valid options See the AT 8700XL Series Software Reference for more information on configuring the switch Using the GUI to configure a router This section describes how to establish a connection to th...

Страница 9: ...able IP enable ip 5 Assign the vlan1 interface an IP address in the same subnet as the PC add ip interface vlan1 ip ipaddress mask mask 6 Save the configuration and set the router to use it on bootup create config your name cfg set config your name cfg 7 On the PC s web browser bypass the HTTP proxy server if necessary 8 Point your web browser at vlan1 s IP address 9 At the login prompt enter the ...

Страница 10: ...he hardware features of AT 8700XL Series switches This Quick Install guide The AT 8700XL Series Software Reference which provides detailed information on configuring the switch and its software The Uplink Module Quick Install Guide which outlines the procedure for installing an Uplink Module and the Uplink Module Hardware Reference which provides detailed information on Uplink Modules AT TFTP Serv...

Отзывы: