background image

 

iii

 

Electrical Safety and Installation 

 

Requirements

 

STANDARDS

 

: This product meets the following standards

RFI Emission EN55022 Class A

 

WARNING

 

: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Immunity EN50082-1

Electrical Safety EN60950, UL1950, CSA 950

 

SAFETY
ELECTRICAL NOTICES
WARNING: ELECTRIC SHOCK HAZARD

 

To prevent ELECTRIC shock, do not remove cover. No user-serviceable parts inside. This unit contains HAZARDOUS VOLTAGES and should only be opened by 
a trained and qualified technician. To avoid the possibility of ELECTRIC SHOCK, disconnect electric power to the product before connecting or disconnecting 
the LAN cables. 

 

LIGHTNING DANGER
DANGER: 

 

DO NOT WORK  on equipment or CABLES during periods of LIGHTNING ACTIVITY.

 

CAUTION

 

: POWER CORD IS USED AS A DISCONNECTION DEVICE. TO DE-ENERGISE EQUIPMENT, disconnect the power cord.

 

INSTALLATION
ELECTRICAL—AUTO VOLTAGE ADJUSTMENT 

 

This product will automatically adjust to any voltage between the ranges shown on the label. 

 

ELECTRICAL—TYPE CLASS 1 EQUIPMENT
THIS EQUIPMENT MUST BE EARTHED.

 

 Power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet 

could place hazardous voltages on accessible metal parts.

 

ELECTRICAL—CORD NOTICE

 

Use power cord, maximum 4.5 meters long, rated 6 amp minimum, 250V, made of HAR cordage molded IEC 320 connector on one end and on the other end 
a plug approved by the country of end use.

 

CAUTION

 

 

Air vents

 

 must 

 

not be blocked

 

 and must have free access to the room ambient air for cooling.

 

OPERATING TEMPERATURE

 

This product is designed for a maximum ambient temperature of

 

 

 

50

 

°

 

 C.

 

ALL COUNTRIES

 

:

 

 Install product in accordance with local and National Electrical Codes.

 

U.S. Federal Communications Commission

 

RADIATED ENERGY

Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits 
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful 
interference  to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will 
be required to correct the interference at his own expense.

Note: Modifications or changes not expressly approved by the manufacturer or the FCC can void your right to operate this equipment. 

 

Canadian Department of Communications

 

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. 

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

Содержание AT-3012SL

Страница 1: ...CentreCOM AT 3012SL AT 3016SL AT 3024SL Multiport Repeaters Installation Guide PN 613 10627 00 Rev A...

Страница 2: ...herein even if Allied Telesyn has been advised of known or should have known the possibility of such damages Trademarks CentreCOM is a registered trademark of Allied Telesyn International Corp Ethern...

Страница 3: ...long rated 6 amp minimum 250V made of HAR cordage molded IEC 320 connector on one end and on the other end a plug approved by the country of end use CAUTION Air vents must not be blocked and must have...

Страница 4: ...tionalen elektrischen Vorschriften entsprechen STANDARDER Dette produkt tilfredsstiller de f lgende standarder Radiofrekvens forstyrrelsesemission EN55022 Klasse A ADVARSEL I et hjemligt milj kunne de...

Страница 5: ...n 50 graden Celsius ALLE LANDEN het toestel installeren overeenkomstig de lokale en nationale elektrische voorschriften NORMES ce produit est conforme aux normes de suivantes Emission d interf rences...

Страница 6: ...d Emissione RFI interferenza di radiofrequenza EN55022 Classe A AVVERTENZA in ambiente domestico questo prodotto potrebbe causare radio interferenza In questo caso potrebbe richiedersi all utente di p...

Страница 7: ...koder PADR ES Este produto atende aos seguintes padr es Emiss o de interfer ncia de radiofrequ ncia EN55022 Classe A AVISO Num ambiente dom stico este produto pode causar interfer ncia na radiorrecep...

Страница 8: ...R con el conector moldeado IEC 320 en un extremo y con un enchufe que est aprobado por el pa s de uso final en el otro INSTRUCCIONES DE MONTAJE ATENCION Estos modelos est n dise ados para operar en po...

Страница 9: ...ena nden och i den andra en plugg som godk nts i landet d r produkten anv nds VARNING Luftventilerna f r ej blockeras och m ste ha fri tillg ng till omgivande rumsluft f r avsvalning DRIFTSTEMPERATUR...

Страница 10: ......

Страница 11: ...l 3 LEDs 4 Switches 5 MDI MDI X Switch 6 Chapter 2 Installation 9 Site Requirements 9 Ventilation 9 Power 9 Port Configurations 10 Station Ports 10 Cable Requirements 10 Installation 10 Link Testing 1...

Страница 12: ...to Hub Wiring 21 MDI MDI X Switch 21 10Base5 Thick Ethernet 23 AUI Cables 23 10Base2 Thin Ethernet 23 Appendix B Glossary 25 Appendix C Technical Support Fax Order 29 Incident Summary 29 Appendix D Ce...

Страница 13: ...in Ethernet This interconnection makes it possible for the repeater to connect to different media thick or thinnet coaxial fiber optic and twisted pair using an external transceiver The AT 3012SL AT 3...

Страница 14: ...egment and re connect it Jabber Lock up Protection Jabber lock up protects the repeater from being overrun with data packets from a possibly defective device That is jabber lock up automatically preve...

Страница 15: ...SL Front Panel Figure 2 AT 3016SL Front Panel POWER 10BASE T PORT ACTIVITY BNC STATUS AUI 10BASE T NETWORK PORTS NETWORK UTILIZATION 1 2 3 4 5 6 7 8 9 10 11 12 TERMINATOR RECEIVING RECEIVING OFF ON PA...

Страница 16: ...n lights when power is applied Activity hub status Green indicates the repeater is functional and is transmitting packets Collision hub status Yellow indicates a data collision on a network port Recei...

Страница 17: ...Switch POWER 10BASE T PORT ACTIVITY BNC STATUS AUI 10BASE T NETWORK PORTS NETWORK UTILIZATION 1 2 3 4 5 6 7 8 9 10 11 12 TERMINATOR RECEIVING RECEIVING OFF ON PARTITION PARTITION MDI MDI X 1 2 3 4 5 6...

Страница 18: ...he other end When connecting two hubs via the 10Base T port or when when connecting two hubs via the network port you must use the one of the following a special crossover cable available commercially...

Страница 19: ...rong position Figure 7 AT 3012SL MDI MDI X Switch POWER 10BASE T PORT ACTIVITY BNC STATUS AUI 10BASE T NETWORK PORTS NETWORK UTILIZATION 1 2 3 4 5 6 7 8 9 10 11 12 TERMINATOR RECEIVING RECEIVING OFF O...

Страница 20: ......

Страница 21: ...ower The repeaters have a universal power supply that will accept either 100 120 or 200 240 VAC power at 50 or 60 Hz as appropriate Check your facility electrical service availability before installin...

Страница 22: ...in a location with adequate ventilation and power receptacles 3 Apply power to the repeater by attaching its power cable Check that the green POWER LED on the front panel lights 4 Attach 10Base T UTP...

Страница 23: ...ransceiver connection intact connect the other end of the cable in turn to each of the other 10Base T ports and check the LEDs Using existing network devices 1 Establish a network connection from Port...

Страница 24: ...the RJ 45 connector from Port 2 and connect it to the unit s remaining 10Base T ports to verify functionality 3 If all ports test successfully install the remaining 10Base T RJ 45 connections and make...

Страница 25: ...lation Use only UTP cable Category 3 or above designed for use in 10Base T applications 10Base T wiring lengths should not exceed 100 meters 328 ft The wiring should be routed away from devices known...

Страница 26: ......

Страница 27: ...0 Meters maximum Category 3 5 UTP cable wired Pin to Pin POWER 10BASE T PORT ACTIVITY BNC STATUS AUI 10BASE T NETWORK PORTS NETWORK UTILIZATION 1 2 3 4 5 6 7 8 9 10 11 12 TERMINATOR RECEIVING RECEIVIN...

Страница 28: ...6 COLLISION COLLISION 1 2 4 8 16 32 64 84 ACTIVITY COLLISION POWER IEEE 802 3 ETHERNET 10BASE T MULTIPORT REPEATER POWER 10BASE T PORT ACTIVITY BNC STATUS AUI 10BASE T NETWORK PORTS NETWORK UTILIZATIO...

Страница 29: ...1 1 1 1 2 2 2 2 3 3 3 3 6 6 6 6 COLLISION COLLISION 1 2 4 8 16 32 64 84 ACTIVITY COLLISION POWER IEEE 802 3 ETHERNET 10BASE T MULTIPORT REPEATER POWER 10BASE T PORT ACTIVITY BNC STATUS AUI 10BASE T NE...

Страница 30: ...OR RECEIVING RECEIVING OFF ON PARTITION PARTITION MDI MDI X 1 2 3 4 5 6 7 8 9 10 11 12 RECEIVING LINK X X X X X X X X X X X 1 1 1 1 2 2 2 2 3 3 3 3 6 6 6 6 COLLISION COLLISION 1 2 4 8 16 32 64 84 ACTI...

Страница 31: ...rious grades of voice quality and data quality cables available These can appear to be similar externally although their high speed data transmission characteristics are radically different If any voi...

Страница 32: ...ice such as a workstation Network Interface Controller NIC This configuration uses a straight through cable as shown in Figure 13 Figure 13 10Base T UTP Cabling Hub to MAU or NIC Straight Through Figu...

Страница 33: ...is the MDI X switch The straight through crossover switch merely provides convenience in having to obtain an alternate cable in some applications If you connect a cable and it does not work try chang...

Страница 34: ...our network may have a high data error rate In a straight through cable the transmit pins 1 and 2 are paired as are the receive pins 3 and 6 In a crossover cable Figure 16 pins 1 and 2 TD and TD are p...

Страница 35: ...as used for computing the worst case propagation delay of a cable system AUI cable propagation delay is approximately 5 13 ns meter This cable internally consists of four shielded twisted pair wires w...

Страница 36: ......

Страница 37: ...impressed on the coaxial transmission medium At any point on the medium only one information signal at a time can be present without disruption BAYONET NUT COUPLE BNC CONNECTOR A 10Base2 thin coax con...

Страница 38: ...See SQE HOUSE WIRING House wiring is the existing wiring inside a building This wiring generally originates from one or more wiring closets such as a telephone room Some older buildings may have wiri...

Страница 39: ...the back which is wired to a punch down block This provides a convenient way for the installer or network manager to connect the hub 10Base T ports into the desired building locations POLARITY CORRECT...

Страница 40: ...E Test STRAIGHT THROUGH A type of wiring connection where the pins of one connector connect to the same pins of another connector For example pin 1 of one connector connects to pin 1 of another connec...

Страница 41: ..._____________ Conditions List the steps that led up to the problem ___________________________ ____________________________________ ____________________________________ _______________________________...

Страница 42: ......

Страница 43: ...nfigurations ______ Data Cabling Techniques _______ Reading the LEDs ______ I found the following the most valuable ______________________________ _____________________________________________________...

Страница 44: ......

Страница 45: ...l 416 675 6738 Fax 416 675 0057 Richmond British Columbia Tel 604 244 0678 Fax 604 270 3644 England Abingdon Oxon Tel 44 1235 442500 Fax 44 1235 442590 France Les Ulis Tel 33 1 60921525 Fax 33 169 28...

Страница 46: ......

Страница 47: ...iguration 16 collision led 13 compliance IEEE 21 IEEE 802 3 19 configurations 15 connectors RJ 45 19 20 crossover cable 6 D data communications equipment DCE 20 DTE 20 23 E Ethernet 23 G glossary 25 H...

Страница 48: ...ck installation 7 R retiming 2 S segmentation 2 site requirements 9 station ports 10 straight through cable 7 T transceiver 1 11 U UTP cable 13 V ventilation 9 W wiring 6 19 20 21 22 23 25 AUI drop sp...

Отзывы: