background image

A R 7 2 0   R O U T E R   Q U I C K   S T A R T   G U I D E

13

Configuring ISDN

3

   In countries other than the USA, the router’s ISDN

directory numbers and subaddresses may be set with
the command:

SET Q931=0 NUM1=

number 

NUM2=

number

SUB1=

subaddress 

SUB2=

subaddress

This step is only required if the router is sharing the ISDN S/T
bus with other ISDN devices. See the 

AR Series Router Software

Reference 

for more information.

Go to Step 5.

4

   In the USA, the ISDN switch type and SPIDs values may also

need to be set. Setting the system territory to USA
automatically sets the ISDN switch type to National ISDN-1.
This should be correct for all new ISDN installations. If the
router is to be connected to another switch type, the switch
type can be set with the command:

SET Q931=0 PROFILE=DMS-100

for a Northern Telecom DMS-100 switch running custom
software, or:

SET Q931=0 PROFILE=5ESS

for a Lucent 5ESS switch running custom software.

If the switch type is not National ISDN-1, the SPIDs (supplied
by the ISDN service provider) must also be entered with
the command:

SET Q931=0 SPID1=

spid

 SPID2=

spid

If the switch type is National ISDN-1 the router will, when first
turned on, attempt to obtain the SPIDs itself from the switch
using the Auto SPID procedures. The success of this procedure
can be monitored with the command:

SHOW Q931=0 SPID

If the Auto SPID procedure succeeds the router will either
select the SPID values to use by itself, or tell the user (in the
output of the SHOW Q931=0 SPID command) how to select
the SPID values.

If the Auto SPID procedures fail, SPIDs can be entered manually
with the command:

SET Q931=0 SPID1=

spid

 SPID2=

spid

This section describes how to configure ISDN on the AR720
router using the command line interface. ISDN on the router
requires minimal user configuration, other than selecting a
territory, creating call definitions and configuring the Point-to-
Point Protocol (PPP) to use the ISDN calls. The lower layers of
the ISDN protocol stack (BRI, LAPD and Q.931) are
automatically configured when the router starts up.

Warning: The factory default hardware and software
settings described here are correct for European Union
(EU) countries. For other countries, contact your distributor
or reseller for details of local requirements.

CONFIGURING BASIC RATE ISDN

To configure Basic Rate ISDN on the AR720 router, follow
these steps:

1

   Check the BRI hardware configuration. The AR720 router

can only operate in TE mode and is shipped with the standard
100

 termination jumpers removed. This is appropriate for

most situations, where the building wiring provides the ISDN
termination. Your distributor or reseller can advise you whether
or not termination jumpers should be installed.

2

   Select the country in which the router is being operated,

using the command:

SET SYSTEM TERRITORY={AUSTRALIA|CHINA|

EUROPE|JAPAN|KOREA|NEWZEALAND|USA}

The territory determines which Q.931 profile is used on the
ISDN interface. For example, to select the Q.931 profile for the
United States, use the command:

SET SYSTEM TERRITORY=USA

Warning: If you are not sure which territory to use, contact
your distributor or reseller. Failure to select the correct
territory will invalidate the approval of this product with
respect to the applicable national standards for the
country in which the product is used.

For installations in the USA, go to step 4. For installations in
other countries, go to step 3.

Содержание AR720

Страница 1: ...Simply connecting the world AR720 ROUTER QUICK START GUIDE Software Release 2 3 1...

Страница 2: ...written notice The information provided herein is subject to change without notice In no event shall AlliedTelesyn be liable for any incidental special indirect or consequential damages whatsoever inc...

Страница 3: ...to a Basic Rate S T ISDN Service 9 Connecting to a Basic Rate U ISDN Service 9 Connecting to a Primary Rate ISDN Service 10 Connecting a Terminal or Modem 10 Documentation andTools CD ROM 12 Using th...

Страница 4: ...etwork Many small offices and home offices require fast and efficient access to a central office to check email access a database or download a file The AR720 supportsWindows Novell and Apple Macintos...

Страница 5: ...etworking via Frame Relay Point to Point Protocol and X 25 Basic Rate and Primary Rate access to Integrated Services Digital Network ISDN services with dial on demand bandwidth on demand and channel a...

Страница 6: ...for the PC but the most readily available are the Terminal and HyperTerminal applications included in Microsoft Windows 3 1 and Windows 95 respectively In a normal Windows installation Terminal is lo...

Страница 7: ...yperTerminal group Double click the Hypertrm exe icon 2 In the Connection Description dialog box enter a name for the connection e g AR720 and select an icon from the scrolling list Click OK 3 In the...

Страница 8: ...Ethernet LAN via an AUI interface use a transceiver ETHERNET PORTS FD LNK RX C R 100 COL 0 1 TX Connect the LAN to the Ethernet port on the rear panel of the AR720 using the supplied CAT 5 cable Data...

Страница 9: ...d is shipped with the standard 100 termination jumpers removed This is appropriate for most situations where the local building wiring provides the ISDN termination Your distributor or reseller can ad...

Страница 10: ...to the PRI interface on the rear panel of the AT AR020 PRI E1 T1 PIC If the router is being connected to a 75 network an external balun is required Contact your distributor reseller or ISDN service p...

Страница 11: ...of how to change the communications settings for the terminal or modem If the terminal or modem is to be used with communications settings other than the default settings the asynchronous port must be...

Страница 12: ...ortcuts and commands from the Document menu to page through the document Click on a bookmark thumbnail or hypertext link to jump to a specific section or topic Use the Search command to search for key...

Страница 13: ...command SET Q931 0 SPID1 spid SPID2 spid This section describes how to configure ISDN on the AR720 router using the command line interface ISDN on the router requires minimal user configuration other...

Страница 14: ...AL SEARCHSUB LOCAL NUMBER 9876543 PREC OUT Each call has the same name ROHO and this name is passed via the called subaddress IE to provide identification to the remote end of the link Each router wil...

Страница 15: ...initiate the call but calls from the Remote Office have precedence On the Head Office router create a call to the Remote Office router ADD ISDN CALL ROHO OUTSUB LOCAL SEARCHSUB LOCAL NUMBER 1234567 PR...

Страница 16: ...and any routing protocols such as IP and IPX that are configured to use PPP interface 0 will automatically inherit the dial on demand functionality CONFIGURING ISDN BANDWIDTH ON DEMAND A PPP interface...

Страница 17: ...er Remote Office Router eth0 Ethernet interface eth0 172 16 8 33 Ethernet interface IP address 192 168 31 30 172 16 8 0 Ethernet LAN IP subnet address 192 168 31 16 255 255 255 0 Ethernet LAN IP subne...

Страница 18: ...rs can exchange information about routes to all of the IP devices hosts PCs file servers etc on the internet However on a dial on demand ISDN connection this may result in excessive call charges So fo...

Страница 19: ...uter Check that RIP is configured correctly steps 4 and 5 above Check that the IP Telnet server is enabled on each router using the command SHOW IP If the Telnet server is disabled enable the Telnet s...

Страница 20: ...required to configure a pair of AR720 routers to create a Novell IPX internetwork using the router s command line interface In this scenario PCs at a remote office need access to a Novell file server...

Страница 21: ...network in a Novell internet including all LANs and WAN links must be assigned a network number Novell file servers also have an internal network number These network numbers must be unique across th...

Страница 22: ...can be caused by a number of different events The following give some of the most common 1 Check that when the workstation is moved to the same LAN as the file server it is able to access the server...

Страница 23: ...2 INT PPP0 NETW 129 DEMAND ON SET IPX CIRC 2 RIPCHANGE YES SAPCHANGE YES 3 Repeat this procedure on the Remote Office router defining one IPX circuit for the Ethernet interface and one for the wide ar...

Отзывы: