It is recommended that this furnace be inspected by a
qualified service technician at the beginning of each heating
season.
Filters
Filters should be checked at least every 6 weeks. Disposable
filters should be replaced when dirty, and cleanable filters
should be cleaned regularly. It is important to keep the air filters
clean, as dirty filters can restrict airflow and the blower and
induced draft motors depend upon sufficient air flowing across
and through them to keep from overheating.
Burners
Light the burners and allow to operate for a few minutes to
establish normal burning conditions. Observe the burner
flames. Compare this observation to Figure 39 to determine if
proper flame adjustment is present. Flame should be
predominantly blue in color and strong in appearance. Check
that all burners are lit, and that the flame does not impinge on
the sides of the heat exchanger.
Distorted flame or yellow tipping of the natural gas burner
flame, or long yellow tips on propane, may be caused by lint
accumulation or dirt inside the burner or burner ports, at the
air inlet between the burner and manifold pipe, or
obstructions over the burner orifice.
Use a soft brush or vacuum to clean the affected areas.
MAINTENANCE
Failure to follow the safety warnings exactly could result
in dangerous operation, serious injury, death, or property
damage.
Improper servicing could result in dangerous operation,
serious injury, death, or property damage.
• Before servicing, disconnect all electrical power to
furnace.
• When servicing controls, label all wires prior to
disconnecting. Reconnect wires correctly.
• Verify proper operation after servicing.
WARNING
ELECTRICAL SHOCK, FIRE,
OR EXPLOSION HAZARD
Lubrication
The blower motor and induced draft motor are pre-lubricated
by the manufacturer and do not require further lubricating
attention. However, the motors should be cleaned
periodically to prevent the possibility of overheating due to
an accumulation of dust and dirt on the windings or on the
motor exterior.
Typical Flame Appearance
Figure 39
Heat
Exchanger
Burner
Flame
(Blue Only)
Burner
Gas
Manifold
Содержание 80G1UH2V
Страница 29: ...506471 01 Page 29 of 41 Issue 1034 ADJUSTING AIRFLOW Table 11 ...
Страница 39: ...506471 01 Page 39 of 41 Issue 1034 Typical Field Wiring Diagram Figure 41 ...
Страница 40: ...506471 01 Page 40 of 41 Issue 1034 START UP PERFORMANCE CHECK LIST UNIT SET UP ...
Страница 41: ...506471 01 Page 41 of 41 Issue 1034 UNIT OPERATION ...