Contact your dealer if you desire more information about
this important safety feature.

Should any unusual conditions be observed during your
inspections, call an authorized service dealer immediately.

Return Air

All return air duct connections must be tight and sealed
to unit cabinet.  Supply and return air registers must be
open when the unit is in operation.  Obstructions must
not be allowed to block airflow in or out of the registers.

Filters

Air filters are to be used with this heating/cooling unit.
Filters are not factory supplied in the unit.  However,

Table 1

Minimum Required Surface Area

for Disposable Filters

the return air compartment includes provisions that allow
filters to be installed within the unit.  Otherwise, a filter
must be installed in the duct work by the installer.  Filters
must always be installed ahead of the evaporator coil and
must be kept clean or replaced. Dirty filters will reduce
the airflow of the unit.  Filters should be sized in accordance
with Table 1.

Outdoor Coil

Leaves and other large obstructions should be carefully
removed from the outdoor coil surfaces without damaging
the fin surface of the coil.

Lubrication

Lubrication of the bearings in the circulating air blower motor
and the combustion blower motor is not recommended.

Blower Assembly

Even with good filters properly in place, blower wheels
and motors will become dust laden after long months of
operation.  The entire blower assembly should be inspected
annually.  If the motor and wheel are heavily coated with
dust, they can be brushed and cleaned with a vacuum
cleaner.

Typical Flame Appearance

Figure 3

Burner Flame

While the unit is in operation, observe the burner flames.
Compare these observations to Figure 3 to determine if
proper flame adjustment is present.  If your observations
indicate improper flame adjustment, call your authorized
service dealer for service.  

Do not attempt to adjust

flame!

 Your service representative will perform this

adjustment correctly.

Rollout Switch

This unit is equipped with a manual reset high temperature
sensor or rollout switch.  In the unlikely event of a sustained
burner flame rollout, the rollout switch will shut off the flow of
gas by closing the gas valve.  The switch is located inside
the gas burner area.  Flame rollout can be caused by
blockage of the power vent system, a blocked heat
exchanger, or improper gas pressure or adjustment.  If this
event occurs, the unit will not operate properly.  The gas
supply to the unit should be shut off and 

no attempt should

be made to place it in operation.

  The system should be

inspected by a qualified service technician.

Содержание 506299-01

Страница 1: ...E OF CONTENTS IMPORTANT SAFETY INFORMATION 2 OPERATING YOUR UNIT 3 MAINTENANCE OF YOUR UNIT 5 REPAIR PARTS 7 WARRANTY 8 Do not store or use gasoline or other flammable vapors and liquids in the vicini...

Страница 2: ...nspect the unit and to replace all gas controls control system parts electrical parts that have been wet or the unit if deemed necessary 6 Examine the unit installation to determine that A All flue ga...

Страница 3: ...ired point When the room thermostat is satisfied the electrical circuit to the gas valve is opened and the burners are shut off Shutting Down the Unit To shut down the unit set the thermostat to the O...

Страница 4: ...ture you would like the system to maintain Fan Operation You may wish to increase your comfort by setting your system for continuous air circulation of the indoor air The fan switch on the thermostat...

Страница 5: ...t the unit The vent motor should start and purge the system for 30 seconds After the prepurge time the burners should ignite If the burner does not ignite contact a qualified service technician for as...

Страница 6: ...he circulating air blower motor and the combustion blower motor is not recommended Blower Assembly Even with good filters properly in place blower wheels and motors will become dust laden after long m...

Страница 7: ...roup Heat exchanger Flue cover Blower Group Blower assembly Blower housing Blower motor Inducer Group Pressure switch Electrical Group Limit switch Fan control board Ignition control Cooling Group Com...

Страница 8: ...b proof of required periodic maintenance installation date and location and c an accurate description of the problem WARRANTY LIMITATIONS 1 This Limited Warranty is void if the covered equipment is r...

Страница 9: ...cycled waste water fertilizers or other damaging substances or other conditions beyond the control of Allied Air 2 Use of parts accessories or refrigerant not compatible with the unit 3 Modification c...

Страница 10: ...Page 10 506299 01 Issue 0912 NOTES...

Отзывы: