NOTE: This machine includes an extended tumble
feature. Starting 20 minutes after a cycle ends, the
cylinder will tumble for two minutes every hour
without heat, up to 18 hours or until door is
opened.
Power-Up Mode
When power is applied to the tumble dryer the control
will enter Ready Mode, unless a cycle was in process
prior to a disruption of power. If a power disruption is
less than 5 seconds, with a cycle in process, the control
will enter Run Mode once power is restored and
continue the cycle. If a power disruption is more than
5 seconds, with a cycle in process, the control will
enter Start Mode once power is restored.
If the dry time dipswitch settings have not changed
from the factory default, the
IN USE
LED will flash
two to five times, depending on model.
Ready Mode
In Ready Mode, the control waits for the vend to be
satisfied before entering Start Mode.
Start Mode
In Start Mode, the vend has been satisfied, but the
Start button has not been pressed. The
IN USE
LED
will be lit. The timer will not count down until the
Start button is pressed.
Run Mode
In Run Mode, the control is running a cycle. The
IN
USE
LED is lit.
Door Open Mode
In Door Open Mode, the control turns off the heater
and motor when the door is opened during a run cycle.
The timer will continue to count down time and the
IN
USE
LED is lit.
End of Cycle Mode
In End of Cycle Mode, a cycle is complete and the
IN
USE
LED is off. The control remains in this mode
until the door is opened or additional vend has been
satisfied.
Topoffs
Any time the control receives a coin drop pulse during
a cycle it will add the programmed dry time to the time
currently remaining in the cycle. The maximum cycle
time is 99 minutes, the control will not add time
beyond 99 minutes. The cool down time will not
change.
If the control receives a coin drop pulse during cool
down the
IN USE
LED will flash briefly to indicate the
coin input, the machine will exit cool down and it will
start heating. The cycle time will be equal to the
programmed dry time.
Temperature Selector Switch
For five minutes after the control is powered up, there
is a diagnostic feature that allows the temperature
selector switches to be tested.
When the temperature selector is changed, the new
setting is displayed by flashing the
IN USE
LED as
follows:
High/Normal: 4 flashes
Medium/PP: 3 flashes
Low/Delicate: 2 flashes
No Heat: 1 flash
NOTE: To change dipswitch settings refer to
Single
Drop Timer Section
.