Electrical Requirements
70457901ENR7
50
050 and 075 Series Electric Models
Serial Plate Rating
Terminal Block
Connections Required
Serial Plate Amps
Recommended Circuit
Nonreversing Reversing
Breaker
Rating
Wire Size
AWG (mm
2
)
240V/50Hz/1ph
(050 Series only)
L1, Neutral and Ground
93
95
125A – 1 pole
1 (35)
200-208V/60Hz/3ph
L1, L2, L3 and ground
89
88
125A – 3 pole
1 (35)
200V/50Hz/3ph
L1, L2, L3 and ground
84
85
125A – 3 pole
1 (35)
230V/50Hz/3ph
L1, L2, L3 and ground
73
75
100A – 3 pole
3 (26.7)
240V/50Hz/3ph
L1, L2, L3 and ground
79
78
100A – 3 pole
3 (26.7)
240V/60Hz/3ph
L1, L2, L3 and ground
79
78
100A – 3 pole
3 (26.7)
380V/50 or 60Hz/3ph
L1, L2, L3 and ground
47
48
60A – 3 pole
6 (16)
400-415V/50Hz/3ph
L1, L2, L3 and ground
43
44
60A – 3 pole
6 (16)
440V/60Hz/3ph
L1, L2, L3 and ground
41
41
51A – 3 pole
6 (16)
480V/60Hz/3ph
L1, L2, L3 and ground
38
38
50A – 3 pole
6 (16)
Table 10