Adjustments
Adjustments
WARNING
To reduce the risk of electric shock, fire, explosion,
serious injury or death:
• Disconnect electric power to the tumble dryer be-
fore servicing.
• Close gas shut-off valve to gas tumble dryer be-
fore servicing.
• Close steam valve to steam tumble dryer before
servicing.
• Never start the tumble dryer with any guards/
panels removed.
• Whenever ground wires are removed during serv-
icing, these ground wires must be reconnected to
ensure that the tumble dryer is properly ground-
ed.
W002R1
Gas Burner Air Shutter
NOTE: Air inlet shutters on the burner must be adjust-
ed so sufficient air is metered into the system for prop-
er combustion and maximum efficiency. Before adjust-
ing the inlet shutters be sure that all lint is removed
from lint compartments and lint screen.
Air shutter adjustments will vary from location to location and
will depend on the vent system, number of units installed, make-
up air and line gas pressure. Opening the shutter increases the
amount of primary air supplied to the burner while closing the
shutter decreases the primary air supply. Adjust air shutter as fol-
lows:
Refer to
Figure 64
.
1.
Open the access panel and remove the burner inspection hole
plate.
TMB2410N_SVG
Figure 63
2.
Start the tumble dryer and check the flame pattern. If the
flame pattern is straight up, insufficient air is flowing through
the tumble dryer. A flame pattern that flares to the right and
left indicates no air is flowing through the tumble dryer. Cor-
rect air and gas mixture is indicated if the flame pattern is pri-
marily blue, with small yellow tips, and bends to the right of
the heater section. Too little air is indicated if the flame if yel-
low, lazy and smokey.
3.
To adjust the air shutter, loosen air inlet shutter adjusting
screw.
4.
Open or close air shutter as necessary to obtain proper flame
intensity.
5.
After air shutter is adjusted for proper flame, tighten air shut-
ter adjusting screw securely.
Adjustments
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
90
Part No. 70457901ENR12