075 Series Gas and Steam Models
Serial Plate Rating
Terminal Block
Connections Re-
quired
Serial Plate Amps
Recommended Circuit
Nonre-
versing
Revers-
ing
Breaker
Rating
Wire Size
AWG
[mm
2
]
120V/60Hz/1ph
L1, Neutral and ground
13.8
N/A
20A – 1 pole
12 [4]
120/208-240V/60Hz/1ph
L1, L2, Neutral and ground 13
13
20A – 1 pole
12 [4]
208-240V/60Hz/1ph
L1, L2, Neutral and
ground
7.6
N/A
20A – 1 pole
12 [4]
200-208-240V/60Hz/1ph
L1, L2 and ground
7.6
N/A
15A – 2 pole
14 [2.5 ]
230-240V/50Hz/1ph
L1, Neutral and ground
6.7
7.0
15A – 1 pole
14 [2.5 ]
200-208/240V/60Hz/3ph
L1, L2, L3 and ground
3.8
4.3
10A – 3 pole
14 [2.5 ]
200V/50Hz/3ph
L1, L2, L3 and ground
3.5
4.5
10A – 3 pole
14 [2.5 ]
230-240V/50Hz/3ph
L1, L2, L3 and ground
3.5
4.9
10A – 3 pole
14 [2.5 ]
380V/50 or 60Hz/3ph
L1, L2, L3 and ground
1.8
2.1
10A – 3 pole
14 [2.5 ]
400-415V/50Hz/3ph
L1, L2, L3 and ground
1.8
2.1
10A – 3 pole
14 [2.5 ]
440V/60Hz/3ph
L1, L2, L3 and ground
1.9
2.1
10A – 3 pole
14 [2.5 ]
460-480V/60Hz/3ph
L1, L2, L3 and ground
1.9
2.1
10A – 3 pole
14 [2.5 ]
N/A = Not Applicable
Table 9
F75 Gas Models Only
Serial Plate Rating
Terminal Block
Connections Re-
quired
Serial Plate Amps
Recommended Circuit
Nonre-
versing
Revers-
ing
Breaker
Rating
Wire Size
AWG
[mm
2
]
200-208/240V/60Hz/3ph
L1, L2, L3 and ground
N/A
6.3
15A – 3 pole
14 [2.5 ]
460-480V/60Hz/3ph
L1, L2, L3 and ground
N/A
3.1
10A – 3 pole
14 [2.5 ]
N/A = Not Applicable
Table 10
Electrical Requirements
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
60
Part No. 70457901ENR12
Содержание YU050E