Dew Point Sensors
–
Mini
User Manual v1.1
www.compressedairalliance.com
16
Wiring - Mini Dew Point Sensor
The Mini series Dew Point Sensor has an M8
connector.
Do
not
screw the M8 connector using force.
Otherwise, it may damage the connection pins.
The data cable will be coloured coded as shown in the
table below. Its good practice to check the cable
colours and make sure they match the chart below.
Connector
Cable Colour
Pin 1
RS845, Data + (A)
Brown
Pin 2
RS845, Data - (B)
White
Pin 3
4-20mA Output
Blue
Pin 4
+12-30 vDC
Black
Pin 5
0 vDC (Ground for Modbus)
Grey
M8 Connector
plug
Sensor tip