18
505894
Section 3 Troubleshooting
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
8. BURNER IGNITES AND GOES OUT REPEATEDLY – GAS DRYER MODELS
Gas dryer models: Burner ignites
and goes out repeatedly.
Is exhaust
system
improper or
inadequate?
Refer to
Installation
Instructions
(supplied with
unit) for
exhaust
requirements.
Yes
Is weather
hood flapper
restricted?
No
Silicon Carbide
Ignition: Is burner
heat holding
sensor contacts
open?
Replace sensor
or correct gas
supply problem.
No
No
DRY1868S
Refer to
Installation
Instructions
(supplied with
unit) for
exhaust
requirements.
Yes
Is gas supply
insufficient?
Check gas supply
and pressure.
Make sure gas
shut-off valve is
turned on.
Is igniter
cracked?
Replace igniter
and bracket.
Are gas valve
coils
inoperative or
intermittent?
Check coils and
replace
appropriate coils.
Refer to
Dryer
Test Procedures
section.
No
Yes
No
Yes
Yes
Yes
DRY1868S
Содержание ZDE30RGS171CW01
Страница 2: ......