© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
70420301 (EN)
26
Table 1
Country
Code
Gas Type
Group
Supply
Pressure,
mbar
Burner
Orifice
Pressure,
mbar
Capacity/
Model
Diameter,
mm
Quantity
Burner
Orifice
Part No.
DK/NO/
SE/FI/CZ/
EE/LV/LT/
SI/SK
Natural Gas
H
20
8.9
050
075
3.7
3.6
2
3
M401000
M401014
L.P. Gas
B/P
30
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
DE**
Natural Gas
E
20
8.9
050
075
3.7
3.6
2
3
M401000
M401014
LL
25
12.6
050
075
3.7
3.6
2
3
M401000
M401014
L.P. Gas
B/P
30
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
B/P
50
28.5
050
075
2.1
2.0
2
3
M401003
M400999
NL
Natural Gas
L
25
12.6
050
075
3.7
3.6
2
3
M401000
M401014
L.P. Gas
B/P
30
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
BE/FR*
Natural Gas
E+
20/25
No Governor
050
075
3.0
2.9
2
3
M401017
N/A
L.P. Gas
3+
28/37
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
GB/IE/PT/
ES/IT/GR/
LU/CH
Natural Gas
H
20
8.9
050
075
3.7
3.6
2
3
M401000
M401014
L.P. Gas
3+
28/37
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
AT**
Natural Gas
H
20
8.9
050
075
3.7
3.6
2
3
M401000
M401014
L.P. Gas
B/P
50
28.5
050
075
2.1
2.0
2
3
M401003
M400999
CY/IS/MT
L.P. Gas
B/P
30
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
HU
Natural Gas
H
25
8.9
050
075
3.7
3.6
2
3
M401000
M401014
L.P. Gas
B/P
30
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
PL
Natural Gas
H
20
8.9
050
075
3.7
3.6
2
3
M401000
M401014
L.P. Gas
3P
37
No Governor
050
075
2.1
2.0
2
3
M401003
M400999
Burner orifice information at 0-2000 feet (0-600 meters) altitude.
N/A = Part no longer available.
* For Natural Gas, Group E+ applications, convert using L.P. Gas model and replace burner orifice(s).
** For L.P. Gas, Group B/P with 50 mbar supply pressure, convert using Natural Gas model, M411334 regulator spring kit
and burner orifice(s).
Содержание YT050E