background image

NOTE: Water supply faucets should be readily accessi-
ble to permit turning them off when washer is not being
used.

Recommended cold water temperature is 50° to 75° Fahrenheit
[10° to 24° Celsius]. Recommended maximum hot water temper-
ature is 125° Fahrenheit [51° Celsius]. Warm water is a mixture
of hot and cold water. Warm water temperature is dependent upon
the water temperature and the pressure of both the hot and cold
water supply lines.

WARNING

To prevent personal injury, avoid contact with inlet
water temperatures higher than 125° Fahrenheit [51°
Celsius] and hot surfaces.

W748

Water pressure must be a minimum of 20 to a maximum of 120
pounds per square inch [minimum of 138 to a maximum of 827
kPa] static pressure measured at the faucet.

NOTE: Water pressure under 20 pounds per square
inch [138 kPa] will cause an extended fill time in the
washer.

Turn on the water supply faucets and flush the lines for approxi-
mately two minutes to remove any foreign materials that could
clog the screens in the water mixing valve. This is especially im-
portant when installing your washer in a newly constructed or
renovated building. Build-up may have occurred during construc-
tion.

 Connecting Hoses

1.   Remove the two plain rubber washers and two filter screens

from the accessories bag.

2.   Install them into each end of the fill hoses as shown in 

Figure

. The screen must be facing outward.

3.   Screw hose couplings with the filter screens onto the water

faucets until they are finger-tight. Use the red color-coded
hose for the hot water connection and the blue color-coded
hose for the cold water connection.

4.   Then, using a pliers, screw approximately 1/4 turn.
5.   Screw hose couplings from other end of hoses onto the water

mixing valve until they are finger-tight. Make sure the red
color-coded hose from the hot water faucet goes to the water
mixing valve marked “H” and the blue color-coded hose from
the cold faucet goes to the valve marked “C”. Refer to Figure 

Figure 4 

.

6.   Then, using a pliers, screw approximately 1/4 turn.

IMPORTANT: DO NOT cross thread or overtighten
couplings. This will cause them to leak.

7.   Turn water on and check for leaks.
8.   If leaks are found, turn off the water, unscrew hoses and rein-

stall them until there are no leaks.

IMPORTANT: Turn off water supply whenever there
will be an extended period of non-use.

TLW1988N_SVG

HOT

COLD

8

7

6

5

4

3

2

1

1.  

Filter Screen (Screen must be facing outward)

2.  

Fill Hose

3.  

Rubber Washer (Plain)

4.  

Cold Water Connection

5.  

Hot Water Connection

6.  

Install this end of hose to valve connections at rear of
washer.

7.  

Install this end of hose to water supply faucet.

8.  

Faucet

Figure 4

IMPORTANT:
Hoses and other rubber parts deteriorate after extend-
ed use. Hoses may develop cracks, blisters or material
wear from the temperature and constant high pressure
they are subjected to.

All hoses should be checked on a monthly basis for
any visible signs of deterioration. Any hose showing
the signs of deterioration listed above should be re-
placed immediately. All hoses should be replaced ev-
ery five years.

 Connect Drain Hose to Drain

Receptacle

1.   Remove the drain hose from its shipping position on the rear

of the washer by unhooking the hose from the retainer clamp.

2.   Install the drain hose into the drain receptacle (standpipe, wall

or laundry tub) following the instructions below.

NOTE: Drain receptacle must be capable of handling
a minimum of 1-1/4 inch [32 mm] outside diameter
drain hose.

 Standpipe Installation

1.   Check standpipe height. The recommended height for the

standpipe is 36 inches [914 mm]. Standpipes higher than 4
feet [1220 mm] are not recommended.

Installation

©

 Copyright, Alliance Laundry Systems LLC -

 DO NOT COPY or TRANSMIT

  7

  Part No. 204871ENR1

Содержание TC5003WN

Страница 1: ...ers Original Instructions Keep These Instructions for Future Reference CAUTION Read the instructions before using the machine If this machine changes ownership this manual must accompany machine www s...

Страница 2: ......

Страница 3: ...ation 7 Low Standpipe Installation 8 Wall Installation 8 Laundry Tub Installation 8 Position and Level the Washer 9 Plug In the Washer 9 Electrical Requirements 9 Earth Ground Instructions 10 Check Li...

Страница 4: ...ic Control 41 25 in 1048 mm Knob Control 40 75 1035 mm D 53 in 1346 mm E 26 in 660 mm F 0 4 in 10 mm G 25 63 in 651 mm H 29 in 737 mm I 42 75 in 1086 mm J 36 in 914 mm With leveling legs turned into b...

Страница 5: ...Hose Kit if needed Kit includes two fill hoses color coded for hot and cold water If using any other hoses follow these requirements Hoses must be new Hoses must be a minimum of 3 8 in inside diameter...

Страница 6: ..._SVG Figure 3 Connect Fill Hoses WARNING Under certain conditions hydrogen gas may be pro duced in a hot water system that has not been used for two weeks or more HYDROGEN GAS IS EXPLO SIVE If the hot...

Страница 7: ...tight Make sure the red color coded hose from the hot water faucet goes to the water mixing valve marked H and the blue color coded hose from the cold faucet goes to the valve marked C Refer to Figure...

Страница 8: ...e TLW2341N_SVG 4 5 3 2 1 1 Ribbed Portion of Drain Hose 2 Beaded Strap 3 Standpipe 2 in 51mm or 1 1 2 in 40 mm Diameter 4 36 in 914 mm Recommended Height 5 12 in 305 mm Figure 5 Low Standpipe Installa...

Страница 9: ...p and check if the washer is lev el from side to side and front to back 6 If washer is not level tilt washer back to access the front lev eling legs Loosen the locknuts and adjust legs by screwing int...

Страница 10: ...e plugged directly into a polarized three slot effective earth ground receptacle rated 110 120 Volts AC alternating current 15 Amps Refer to Figure 11 to determine correct polarity of the wall recep t...

Страница 11: ...m has an effective earth ground have a qualified electri cian or your local electrical utility company check it and cor rect any problems WARNING This unit is equipped with a three prong earth ground...

Страница 12: ...TLW2281N_SVG1 6 Plug In the Washer TLW2289N_SVG CHECK CHECK 3 Connect Fill Hoses TLW1988N_SVG HOT COLD 7 Add Water to the Washer W391I_SVG CHECK CHECK 4 Connect Drain Hose to Drain Receptacle TLW2288...