VENTING
WARNING
VAPOURS ESCAPE FROM THE MACHINE THROUGH
THE AIR VENT OPENING! REFER TO
. DO
NOT COVER.
The vent air opening is part of the back flow prevention water
system. It also takes care that the tub can not be pressurized by
water intake and vapor of the hot water. It allows also proper
measuring of the water level. For the safety of everyone make
sure that unauthorized persons cannot reach the backside of the
machine. It is possible to connect the machine venting pipe to the
laundry central duct for exhausting the vapor out of the building.
For placing of connection points see
piping material must withstand a temperature of 80°C / 176°F
and generated machine vibrations. The central duct for multiple
venting must be dimensioned for the total cross section of venting
pipes of all machines. Take care that this installation can not cre-
ate any injury at anyway.
ELECTRICAL CONNECTION
The machine has been designed for connecting to the power net-
work according the specification of your order. Before connec-
tion check the voltage values and the frequency stated on serial
plate (
), if they correspond to your power
network. An individual branch circuit needs to be used for each
machine. The way of the connection is described in
.
For electrical protection, there must be installed a residual current
device (RCD) and a circuit breaker in the electrical installation of
the building (laundry switchboard). For correct selection see be-
low.
IMPORTANT:
• If the machine is not equipped with a main switch then supply
disconnecting devices need to be provided in the installation
for all electrical supplies connected to the machine, in accord-
ance with EN 60204-1 standard, point 5.3.
• Make sure the supply voltage is always within the limits
specified in the "Technical specification"
cumstances. When you have long distances in the electrical
installation, it may be necessary to use bigger cables to reduce
the voltage drop.
• When the machine is connected near a large capacity power
supply transformer (500kVA or more, wiring length shorter
than 10 m) or there is a power capacitor switch-over, a power
supply improving reactor must be installed. If you do not in-
stall this, the inverter may get damaged. Contact your distrib-
utor for more information.
WARNING
GROUNDING: IN EVENT OF MALFUNCTION OR
BREAKDOWN OR LEAKAGE CURRENT, THE
GROUNDING WILL REDUCE THE RISK OF ELECTRI-
CAL SHOCK AND SERVE AS A PROTECTING DE-
VICE, BY PROVIDING A PATH OF LEAST RESIST-
ANCE OF ELECTRICAL CURRENT. THEREFORE IT IS
VERY IMPORTANT AND THE RESPONSIBILITY OF
THE INSTALLER TO ASSURE THE WASHER IS ADE-
QUATELY GROUNDED AT THE POINT OF INSTALLA-
TION TAKING INTO CONSIDERATIONS THE NATION-
AL AND LOCAL CONDITIONS AND REQUIREMENTS.
C042
Machine connection to electrical network (with a re-
sidual current device)
1.
Earth leakage trip
2.
Laundry electrical switchboard
3.
Power supply protection
4.
Washing machine
5.
Phase conductors
6.
Protective conductor
7.
Main switch inlet terminal switchboard
8.
Neutral conductor
Figure 20
RESIDUAL CURRENT DEVICE (RCD)
In some countries an RCD is known as an “earth leakage trip” or
“Ground Fault Circuit Interrupter” (GFCI) or an “Appliance
Leakage Current Interrupter” (ALCI) or “earth (ground) leakage
current breaker”.