Installation
21
800534
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Heat Source Check
Electric Dryers
Coin Drop Models
Set the proper FABRIC SELECTOR switch at
NORMAL. Place coins in the slide and carefully push
slide in as far as possible.
IN USE
light will come on
indicating the dryer is ready to operate. Close the
loading door and press the PUSH-TO-START button
firmly to start the dryer. After dryer has operated for
three minutes, the exhaust air or exhaust pipe should
be warm.
Gas Dryers
During the gas heat check, observe the burner flame.
The flame can be viewed by removing the lower front
panel of the dryer.
Coin Drop Models
Set FABRIC SELECTOR switch at NORMAL. Place
coins in the slide and carefully push slide in as far as
possible.
IN USE
light will come on indicating the
dryer is ready to operate. Close the loading door and
press the PUSH-TO-START button firmly. The dryer
will start, the igniter will glow red and the main burner
will ignite.
IMPORTANT: If all air is not purged out of the gas
line, the gas igniter may go off before the gas is
ignited. If this happens, after approximately two
minutes the igniter will again attempt gas ignition.
After dryer has operated for approximately five
minutes, observe burner flame. Adjust the air shutter
to obtain a soft, uniform blue flame. (A lazy yellow-
tipped flame indicates lack of air. A harsh, roaring,
very blue flame indicates too much air.) Adjust the air
shutter as follows:
1. Loosen the air shutter lockscrew.
2. Turn the air shutter to the left to get a luminous
yellow-tipped flame, then turn it back slowly to
the right to obtain a steady soft blue flame.
3. After the air shutter is adjusted for proper flame,
tighten the air shutter lockscrew securely.
4. Reinstall the lower front panel.
After dryer has operated for approximately three minutes,
the exhaust air or exhaust pipe should be warm.
Figure 20
For personal safety, lower front panel of
dryer must be in place during normal
operation.
W288
WARNING
D700I
1
Closed Position
5
1/8" (3.1 mm) Pipe Plug
(For checking manifold pressure)
2
Shutt-Off Valve Handle
3
Air Shutter Lockscrew
6
Open Position
4
Air Shutter
3
4
5
2
1
6
Содержание HTEB17*J99L1
Страница 4: ...2 800534 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 8: ...6 800534 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 10: ...800534 8 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 60: ...800534 58 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 66: ......
Страница 70: ...68 800534 SP Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notas ...
Страница 74: ...72 800534 SP Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notas ...
Страница 76: ...800534 SP 74 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notas ...
Страница 80: ...800534 SP 78 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notas ...
Страница 128: ...800534 SP 126 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notas ...
Страница 134: ...800534 SP 132 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notas ...
Страница 135: ......