F238000
27
Section 4 Service Procedures
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer-extractor before servicing.
• Never start the washer-extractor with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer-extractor is properly grounded.
W171
WARNING
38. LOADING DOOR
a. Support outer front panel while removing six
screws holding panel to front of washer-
extractor, refer to
b. Remove outer front panel and set aside.
c. Remove four nuts holding loading door hinge
to shell front, refer to
.
d. Remove loading door and hinge together.
e. Remove loading door shims.
NOTE: When replacing door hinge, use same
number of shims as existed prior to removal.
Figure 18
B017SE1A
DOOR
SHIMS
LOADING DOOR
HINGE