F238000
17
Section 4 Service Procedures
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer-extractor before servicing.
• Never start the washer-extractor with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer-extractor is properly grounded.
W171
WARNING
23. DOOR LOCK PC BOARD / CAPACITOR
IMPORTANT: To reduce the risk of electrical
shock, touch capacitor terminals with a resistor to
discharge the capacitor.
a. Insert key into cabinet top lock and turn
clockwise. Lift up on front of cabinet top until
it is just past the rear hinges, or 90 degrees, refer
to
. Lift cabinet top off machine and set
out of way.
NOTE: When reinstalling cabinet top, metal edges
on dispenser opening must be fitted inside of
dispenser.
b. Remove two T20 Torx head screws from
control module box cover. Lift up cover and set
aside.
c. Remove positive and negative screws holding
board to capacitor, refer to
.
d. Remove board from capacitor.
e. Remove screws holding capacitor U-clamp to
rear channel. Remove capacitor.
IMPORTANT: When reinstalling capacitor and PC
Board, make sure the positive screw is in the positive
hole, refer to
Figure 6
+
B006SE1A
CAPACITOR
U-CLAMP
NEGATIVE
SCREW
POSITIVE
SCREW
DOOR LOCK
PC BOARD
POSITIVE
HOLE