14
F238000
Section 4 Service Procedures
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer-extractor before servicing.
• Never start the washer-extractor with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer-extractor is properly grounded.
W171
WARNING
19. INDICATOR LIGHTS
a. Insert key into cabinet top lock and turn
clockwise. Lift up on front of cabinet top until
it is just past the rear hinges, or 90 degrees, refer
to
. Lift cabinet top off machine and set
out of way.
NOTE: When reinstalling cabinet top, metal edges
on dispenser opening must be fitted inside of
dispenser.
b. Remove two T20 Torx head screws from
control module box cover. Lift up cover and set
aside.
c. Remove wires from indicator lights.
d. Press in on locking tabs and push lights out
through front of control panel, refer to
Figure 2
B002SE1A
POWER SUPPLY
BOARD
WIRE
HARNESS
COIN
DROP
COIN
BLOCKING
SOLENOID
Figure 3
B003SE1A
WIRES
LOCKING
TABS