26
F238000
Section 4 Service Procedures
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer-extractor before servicing.
• Never start the washer-extractor with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer-extractor is properly grounded.
W171
WARNING
36. MOTOR CAPACITORS
a. Remove screws holding rear panel to cabinet
and remove rear panel.
IMPORTANT: To reduce the risk of electrical
shock, touch capacitor terminals with a resistor to
discharge the capacitor.
b. Disconnect wires from capacitors, refer to
IMPORTANT: When replacing the capacitors, do a
wire-for-wire exchange, or write down all of the
wire terminal connections before removing any
wires. If you have a problem, refer to the wiring
diagram on the underside of the cabinet top.
c. Remove nuts holding capacitors to capacitor
tray and remove capacitor.
37. OUTER FRONT PANEL
a. Support outer front panel while removing six
screws holding panel to front of washer-
extractor, refer to
b. Remove outer front panel and set aside.
Figure 16
B015SE1A
WIRES
(Single Phase
only)
CAPACITORS
CAPACITOR
TRAY
Figure 17
B016SE1A
OUTER
FRONT PANEL
SCREW