Section 4 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To Test Igniter:
1. Disconnect igniter wires at disconnect block.
Refer to Figure 19.
2. Set test meter to read Ohms and put meter probes
on terminals of igniter wires.
3. Meter should register an Ohm reading of at least
40 Ohms at the minimum. If meter registers less
than 40 Ohms, replace the igniter.
IMPORTANT: Always examine all wires,
terminals and connectors to be sure wiring is
proper before replacing any components.
NOTE: Test procedure can be performed on
workbench if gas valve, igniter, burner tube and
burner housing have been removed from dryer.
Figure 19