505872
63
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
60. TERMINAL BLOCK OR POWER CORD
a. Terminal Block – Electric Models (Refer to
Through Serial No. S6270865XG:
(1) Remove access plate on rear of cabinet.
(2) Remove all wires from terminal block.
(Refer to appropriate wiring diagram when
rewiring terminal block.)
(3) Remove screws holding terminal block to
bracket.
NOTE: Do not let terminal block insulation drop
when removing the block. Insulation must be in
place when reinstalling block.
Staring Serial No. S6270866XG:
(1) Remove two screws from the bottom edge
of the front panel. Refer to Figure 14.
(2) Swing the bottom of the panel away from
the dryer to disengage hold-down clips and
guide lugs from cabinet top. Refer to
Figure 14.
(3) Disconnect wires from door switch. Refer
NOTE: Refer to appropriate wiring diagram when
rewiring switch.
(4) Remove two cabinet hold-down screws.
(5) Lift cabinet top to a vertical position by
hinging it on the rear hold-down bracket.
Refer to Figure 38.
NOTE: When servicing, cabinet top may be raised
and hinged on the rear hold-down brackets, or
supported against wall behind the dryer.
(6) Remove all wires from terminal block.
(Refer to appropriate wiring diagram when
rewiring terminal block.)
(7) Remove screw holding terminal block to
bracket.
NOTE: Do not let terminal block insulation drop
when removing the block. Insulation must be in
place when reinstalling block.
b. Power Cord – Gas Models
(1) Remove access plate on rear of cabinet.
(2) Remove strain relief.
Figure 38
DR081-SV-1
THROUGH SERIAL NO. S6270865XG
GROUND
WIRE
STARTING SERIAL NO. S6270866XG
DR082-SV-1
BRACKET
SCREWS
TERMINAL BLOCK
ATTACHING SCREWS
TERMINAL
BLOCK
ATTACHING
SCREW
INSULATION
TERMINAL
BLOCK
BRACKET
BRACE
CABINET TOP
HINGES