© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
9
802749
These terminals may be used to provide signals to the
supply injection system but must not be used to
provide power to the actual pump.
Any injection system pump which requires
110 VAC must be powered by a separate external
power source.
Control Function Test
The washer should be cleaned after the installation is
complete. A function test should then be executed on
the unloaded machine:
1. Check the power supply for such characteristics
as correct voltage, phase, and cycles to be certain
they are correct for the washer.
2. Open manual shut-off valves to the washer.
3. Apply power to the washer.
Step 8: Plug in the Washer
Washer requires 120 Volt, 60 Hertz electrical supply
and comes equipped with a 3-prong grounding plug.
Refer to serial plate for specific electrical
requirements.
When plugging in the washer:
•
DO NOT overload circuits.
•
DO NOT use an extension cord.
•
DO NOT use an adapter.
•
DO NOT operate both a washer and gas dryer on
the same circuit. Use separately fused 15 Amp
circuits.
The washer is designed to be operated on a separate
branch, polarized, three-wire, effectively grounded,
120 Volt, 60 Hertz, AC (alternating current) circuit
protected by a
15 Amp fuse
, equivalent fusetron or
circuit breaker.
The three-prong grounding plug on the power cord
should be plugged directly into a polarized three-slot
effectively grounded receptacle rated 110/120 Volts
AC (alternating current) 15 Amps. Refer to
to determine correct polarity of the wall receptacle.
DRY2022N
1
L1
2
Ground
3
Neutral Side
4
Round Grounding Prong
5
Neutral
Figure 13
1
2
3
4
5
Standard 120 Volt, 60 Hertz
3-Wire Effectively
Grounded Circuit
0 V.A.C.
120±12
V.A.C.
120±12
V.A.C.
To reduce the risk of fire, electric shock or
personal injury, all wiring and grounding
MUST conform with the latest edition of
the National Electrical Code, ANSI/NFPA
70, and such local regulations as might
apply. It is the customer’s responsibility
to have the wiring, fuses and circuit
breakers installed by a qualified
electrician to make sure adequate
electrical power is available to the washer.
WARNING
W518
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the washer to the
electric power source.
W082
WARNING
Содержание 802749r1
Страница 11: ......