Electrical Requirements
45
M414905
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
75 Pound Gas and Steam Models
Refer to
.
NOTE: Wire size and breaker ratings were
obtained from the Canadian Electrical Code for
75 C. wire and are intended for use as a guideline
only. Electrical connections should be made by a
qualified electrical contractor in accordance with
all applicable local and national requirements.
NOTE: Electrical specifications below are subject
to change without notice. Always refer to product
serial plate for most current specifications of
product being installed.
NOTE: Use copper conductors only.
NOTE: Connect to individual branch circuit.
Serial Plate Rating
Terminal Block
Connections
Required
Serial Plate Amps
Recommended Circuit
Nonreversing
Reversing
Breaker
Rating
Wire Size
AWG (mm
2
)
120V/60Hz/1ph
L1, Neutral and ground
13.8
N/A
20A – 1 pole
12 (3.31)
200-208V/60Hz/1ph
L1, Neutral and ground
7.6
N/A
15A – 1 pole
14 (2.08)
200-208-240V/60Hz/
1ph
L1, L2 and ground
7.6
N/A
15A – 2 pole
14 (2.08)
230-240V/50Hz/1ph
L1, Neutral and ground
6.7
7.0
15A – 1 pole
14 (2.08)
200-208V/60Hz/3ph
L1, L2, L3 and ground
3.8
4.3
10A – 3 pole
14 (2.08)
200V/50Hz/3ph
L1, L2, L3 and ground
3.5
4.5
10A – 3 pole
14 (2.08)
240V/60Hz/3ph
L1, L2, L3 and ground
3.8
4.3
10A – 3 pole
14 (2.08)
230-240V/50Hz/3ph
L1, L2, L3 and ground
3.5
4.9
10A – 3 pole
14 (2.08)
380V/50 or 60Hz/3ph
L1, L2, L3 and ground
1.8
2.1
10A – 3 pole
14 (2.08)
400-415V/50Hz/3ph
L1, L2, L3 and ground
1.8
2.1
10A – 3 pole
14 (2.08)
440V/60Hz/3ph
L1, L2, L3 and ground
1.9
2.1
10A – 3 pole
14 (2.08)
460-480V/60Hz/3ph
L1, L2, L3 and ground
1.9
2.1
10A – 3 pole
14 (2.08)
N/A = Not Applicable
Table 7
F75 Gas Models Only
Serial Plate Rating
Terminal Block
Connections
Required
Serial Plate Amps
Recommended Circuit
Nonreversing
Reversing
Breaker
Rating
Wire Size
AWG (mm
2
)
200-208V/60Hz/3ph
L1, L2, L3 and ground
N/A
6.3
15A – 3 pole
14 (2.08)
240V/60Hz/3ph
L1, L2, L3 and ground
N/A
6.3
15A – 3 pole
14 (2.08)
460-480V/60Hz/3ph
L1, L2, L3 and ground
N/A
3.1
10A – 3 pole
14 (2.08)
N/A = Not Applicable
Table 8