STANDARD FEATURES
9) Emergency Battery Operation
In the event of a building power failure, the door/gate system is provided with an temporary
power back up system to continue the opening operation for a number of times. On resuming
normal building power, the back up system will turn OFF and begin automatic recharging.
10) Car Top Inspection Station (CTIS)
The CTIS is installed on all lifts and must be operated by qualified inspectors or Cambridge
Elevating Inc. dealer only. Set to NORMAL for normal lift operation, set to INSPECT with all
doors closed and locked for inspection purposes. Press and hold the ENABLE/SAFETY button,
then press and hold UP or DOWN button to run the cab in the selected direction. Set to the
red Stop Button RUN to allow the cab to run UP/DOWN during inspection, set to STOP to stop
the cab from running at any time.
11) Car Top Prop (When required by site conditions)
The Car Top Prop must be operated by qualified inspectors or Cambridge Elevating Inc.
dealers only. It is supplied when insufficient overhead hoistway clearance exists. Raise and
rotate the Prop counter-clockwise to the service position before operating the CTIS. Ensure
the Prop is stowed to normal position before the lift is returned to normal operation.
TO PREVENT SHEAR HAZARDS WHEN OPERATING THE CTIS, ALWAYS KEEP ALL BODY PARTS
INSIDE THE CAB ROOF EDGES AND AWAY FROM ANY HOISTWAY EXTRUSIONS. THE PIT PROP
MUST BE SET TO THE SERVICE POSITION (WHEN EQUIPPED).
4