background image

PAGE

  10

www.allfett.net

ELECTRICAL CONNECTIONS

Electrical connection box

220 V AC Connection

L

N

W1

V1

U1

380 V AC Connection

R

S

W1

V1

U1

T

220 V AC Control box connection

380 V AC Control box connection

(380 V AC INPUT)

I

O

R

S

T

R S T

(Motor Out)

(220 V AC INPUT)

I

O

L

L N

(Motor Out)

N

If ALL-10 pump will be used with ALLFETT 

EK-9

 external control box, electrical lines must be

connected properly as described in schema below.

Any maintenance on ALL-10 pumps under electrical voltage could lead to personal
injury. Disconnect all electrical power before any maintenance .

Pumps have an electric driven motor. Electrical lines must be connected properly as described in

schema below. Electrical connections are placed on motor.

Содержание Multi Line ALL-10 Series

Страница 1: ...ALL 10 Multi Line Series ELECTRICAL GREASE PUMP INTRODUCTION AND USER MANUAL VERSION 2 00 THE PHYSICAL LIFE DETERMINED BY MINISTRY OF INDUSTRY AND TRADE OF TURKEY IS 10 YEARS ...

Страница 2: ...ill be increased INTRODUCTION ABOUT MANUFACTURER With over 25 years experience of manufacturing Centralized Lubrication Systems ALLFETT is able to provide a wide professional approach to select the correct Centralized Lubrication System for industry and heavy machinery A highly accurate manufacturing process is involved in producing Centralized Lubrication Systems in order that systems meet the ve...

Страница 3: ... DESCRIPTION LUBRICANT INFORMATION STANDARD ELECTRICAL CONNECTION OPTIONAL ELECTRICAL CONNECTION RULES TO COMPLY WHILE USING AND WARRANTY CONDITIONS PUMP MAINTENANCE PUMP ELEMENT MAINTENANCE ORDER INFORMATION WARRANTY WARRANTY CONDITIONS PAGE 1 PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 6 PAGE 7 PAGE 8 9 PAGE 10 PAGE 11 PAGE 12 13 PAGE 14 PAGE 15 PAGE 16 PAGE 17 PAGE 18 ...

Страница 4: ...rease In case the pump is installed so that operator cannot see the level of grease the ALLFETT low level sensor can be used to follow the level of grease Top filling application is possible with different filling covers with or without lock ALL 10 pumps can be controlled and monitored with externall electronic control cards Optional control card feature also displays warnings as broken fuse fault...

Страница 5: ...t is milimeter QUALITY SYSTEM ISO 9001 BUREAU VERITAS Certification This product is produced by ALLFETT Mekanik ve Elektronik Sistemler San Tic Ltd Sti company which is certificated by Bureau Veritas with certificate to compatible for ISO 9001 2008 standard and owner of the quality management system 358mm Ø211 710mm 12 liters 640mm 8 liters 492mm 6 liters ...

Страница 6: ... TECHNICAL SERVICE Standard filling cover Optional Metal filling cover Lockable type Optional Plastic filling cover Optional Plastic filling cover Lockable type Optional Filling type reservoir cover circle type Optional Agitator Reservoir cover standard Reservoir Level indicator Optional Pump element positions 1 20 Pump body 220 380 V AC Electrical motor Motor connection Chassis Gear box ...

Страница 7: ...tiple lubrication points Optional system control units Lubrication system and its components can be controlled and monitored with integrated electronic control cards Digital sensores and also pressure switches where placed on system components send information to control card FUNCTIONAL DESCRIPTION Pump elements distributors and control cards are offered optionally While ordering a pump other comp...

Страница 8: ...when a lubrication point is blocked Up to 450 bar pressure lubrication system s working pressure can be adjusted by security relief valve Lubricant with over pressure will be out from exhoust hole Pump elements are manufactured in 3 types according to diplacement amounts These types can be described as its piston diameter with Ø5 mm piston pump element s outlet displacement is 1 5cm minute with Ø6...

Страница 9: ...rmations Lubricant type GREASE Lubricant will be used in the system must certainly be clean and any foreign materials must not enter while filling ALL 1 pumps are designed to use with in centralized lubrication systems only It is not suitable to use ALL 1 pump for lubricant tranfering or circulation purpose To remind that lubricants has content which may hazardous to environment It is important th...

Страница 10: ... NLGI 0 NLGI 1 NLGI 2 R 1 Ø27mm NLGI 0 NLGI 1 NLGI 2 Ø6 x 1 Ø4mm 10 C 0 C 10 C 20 C 30 C 7 5 cm minute 2 4 4 6 4 4 2 7 11 2 7 8 13 20 8 1 44 2 4 3 84 1 14 1 9 3 2 1 3 5 5 6 3 9 6 5 10 4 0 66 1 1 1 76 0 42 0 7 1 12 0 6 1 1 6 1 1 1 8 2 88 2 16 3 6 5 76 0 3 0 5 0 8 0 18 0 3 0 48 0 36 0 6 0 96 0 66 1 1 1 76 1 32 2 2 3 52 0 18 0 3 0 48 0 1 0 18 0 29 0 84 1 4 2 24 0 12 0 2 0 32 0 27 0 45 0 72 0 6 1 1 6 ...

Страница 11: ...PUT I O L L N Motor Out N If ALL 10 pump will be used with ALLFETT EK 9 external control box electrical lines must be connected properly as described in schema below Any maintenance on ALL 10 pumps under electrical voltage could lead to personal injury Disconnect all electrical power before any maintenance Pumps have an electric driven motor Electrical lines must be connected properly as described...

Страница 12: ...L 10 pump will be used with ALLFETT EK 9 external control card with low level option electrical lines must be connected properly as described in schema below Pressure switch with control card Low level with control card Pressure Pressure signal 3 2 1 9 8 7 6 5 4 3 2 1 Electronic control card socket Pressure switch socket 3 2 1 9 8 7 6 5 4 3 2 1 Low level Low level signal Low level Electronic contr...

Страница 13: ...aterials must not enter while filling 13 Rubber based lubricant types must not be used in the system Damages or faults occur from this reason DISQUALIFIES THE WARANTY 12 Only LITHIUM based and EP additive lubricants must be used with in system 11 Only proper NLGI class lubricants must be used with in system NLGI class must be changed according to weather conditions Use NLGI 0 for cold weather incr...

Страница 14: ...foreign materials dirt or small particules while filling lead to system units failing and possibly property damage Damages or faults occur from this reason DISQUALIFIES THE WARANTY 16 Disassembling or loosing any part while pump working is prohibited Any damage coming from this reason DISQUALIFIES THE WARANTY Also any personal injury occur from this reason ALLFETT does not accept responsibility 18...

Страница 15: ...cause of the grease inside pump decreased under minimum level Fill the reservoir according to items 10 11 12 13 14 15 and 16 in RULES TO COMPLY WHILE USING AND WARRANTY CONDITIONS If ALLFETT control card is connected the system Electronic control card may be in waiting period Wait until working time starts If necessary control card pass to working period by pressing ADDITIONAL CYCLE button a b c d...

Страница 16: ...ump element s outlet coupling Loose pump element from pump body for 2 3 turns Start to operate pump When grease coming from around pump element body tighten again pump element body to pump Pump should run contiuously untill grease without air is seen from pump element outlet When the grease without air seen from pump element outlet coupling must be tightened to outlet again With this process pump ...

Страница 17: ...07 02 10 0260 10 0261 10 12 MT 01 10 24 MT 01 10 00 GL 03 10 00 00 PL 10 00 00 1M 10 00 00 2P 10 00 00 1P Ordering numbers Product name Description ALL 10 Multi line Pump 220 V AC 6 Liters ALL 10 Multi line Pump 220 V AC 8 Liters ALL 10 Multi line Pump 220 V AC 10 Liters ALL 10 Multi line Pump 220 V AC 12 Liters 10 22 06 CH 10 22 08 CH 10 22 10 CH 10 22 12 CH Ordering numbers Product name Descript...

Страница 18: ... WARRANTY PRODUCER COMPANY FAX TELEPHONE CENTRAL ADRESS NAME ALLFETT Mekanik ve Elektronik Sistemler San ve Tic Ltd Þti 0212 501 33 37 0212 501 32 01 PBX Yeni Eyup Bulvari Topcular Cad Set Ustu No 1 Demirkapý Rami Ýstanbul AUTHORISED PERSON SIGNATURE STAMP PRODUCT TYPE Elektrikli gres pompasý BRAND ALLFETT MODEL SERIAL NUMBER DELIVERY DATE PLACE WARRANTY 2 Years REPAIR TIME 30 days ALL 10 Multi Li...

Страница 19: ... exceeded If it is determined that the defect cannot be repaired by report written by the service or in the absence of service centers by the seller agency representative importer or manufacturer of the product respectively The present warranty does not cover damages resulting from importer handling by deviating from the instructions in the manual General administration of protection of consumer r...

Страница 20: ...PAGE 19 www allfett net ...

Отзывы: