![Allfett LUBMATIC Series Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/allfett/lubmatic-series/lubmatic-series_introduction-and-user-manual_2901070009.webp)
PAGE
8
www.allfett.net
ELECTRICAL CONNECTION
After electrical connections are complated, female part of the socket must be tightened
by screw to male part. Use a thin screwdriver to tighten socket screw.
Socket screw
Electrical socket female part
Electrical socket male part
All electrical connections and lines must be checked regularly for damage and to ensure
that they are firmly in place.
ELECTRICAL COUPLING CONNECTIONS
ELECTRICAL SOCKET CONNECTIONS
Pumps have an electric driven motor. Electrical lines must be connected properly as described in
schema below. Electrical connection socket is placed near motor box.
220 V AC
F
N
380 V AC
R
S
T
Electrical cables are marked with connection
details. Electrical connections must be done by
following these markers.
Low level
2
1
Low
level
Low
level
Содержание LUBMATIC Series