Fittings on lubrication lines and distributor may be loose ;
Check all fittings on lines and distributor block. If fittings are loose there should be grease leakage.
Tighten all loose fittings.
Lubrication lines between distributor block and lubrication lines may be crushed, damaged
or blocked ;
If the tube remains crushed by an object, cross section of tube become narrow and may not allow
grease passage. In this case the grease release is visible via security valve. Check the hoses for
crushing. Replace the hoses if necessary.
Tube or lubrication point may blocked inside by dirt. In this case the grease release is visible via
security valve. Check the hoses and lubrication points for blockage. Replace the hoses if necessary.
If the tubes are broken grease will not reach to the lubrication points. Grease leaks from places where
breaked.
System components may installed by crew without ALLFETT authorization ;
If distance between pump, distributor and lubrication lines are too long, grease release is visible via
security valve. Connect with ALLFETT service for further consulting.
Page
13
www.allfett.net
MAINTENANCE INSTRUCTIONS
4. PUMP SENDING TOO MUCH GREASE.
Pump may be controlled by PLC unit ;
Decrease the working time period by programming PLC unit.
Pump may be controlled by ALLFETT electronic control unit ;
Refer to the user manual for the control unit used on system. Contact with ALLFETT service if necessary.
a.
b.
3. GREASE IS NOT COMING OUT FROM DISTRIBUTOR.
a.
b.
c.
Содержание ALL-6