Page
12
www.allfett.net
2. PUMP IS OPERATING BUT NOT SENDING GREASE ;
1. PUMP IS NOT OPERATING.
MAINTENANCE INSTRUCTIONS
Electrical cables of pump may loose or broken ;
Check the electrical cables for proper connection.
Connected electricity may not be DC voltage ;
Connect proper electricity to pump described on the label.
If transformer is used to convert voltace AC to DC ;
Use minimum 5A current transformer.
If Pump is connected to ALLFETT electronic control unit ;
Control unit may be on the waiting period. Wait until working period starts.
When necessary, pressind to additional cycle button on control card operates system for single period.
a.
b.
c.
d.
Grease inside cartridge may empty ;
Replace cartridge with new one by following the steps on PAGE 9 and 10.
Grease may not be appropriate ;
Replace cartridge with appropriate grease. Read PAGE 8 to understand which type of grease is
appropriate.
Pump may taken air inside ;
Instructions explained on page 9 should be read and operated carefully. There must not be air gaps
inside of cartridge place on pump body. After complating cartridge instructions follow the steps below.
Disassemble outlet hoses from distributor block.
Run the pump.
See grease coming from distributor outlets.
Reassemble the hoses to distributor.
a.
b.
c.
Unouthorized modifications to the units and the use of unouthorized spare parts and
aids prohobited also disqualify the warranty.
Содержание ALL-6