OPTIONAL COMPONENTS

High pressure tube - Ø11,3xØ6,35 - 840 bar.
Barrel type follover plate
Barrel cover
Grease gun
“Z” Joint

51 00 05 05
20 00 20 00
10 0687
10 GT 00 00
10 ZM 00 00

Order number

Product name

Order number

Product name

ALL-5 Two Line Bucket - 220 V AC - Ø12mm piston
ALL-5 Two Line Bucket - 220 V AC - Ø16mm piston
ALL-5 Two Line Bucket - 220 V AC - Ø20mm piston

10 22 16 D1
10 22 16 D2
10 22 16 D3

ALL-5 Two Line Bucket - 380 V AC - Ø12mm piston
ALL-5 Two Line Bucket - 380 V AC - Ø16mm piston
ALL-5 Two Line Bucket - 380 V AC - Ø20mm piston

11 38 16 D1
11 38 16 D2
11 38 16 D3

Содержание ALL-5 Two Line

Страница 1: ...ALL 5 Two Line Bucket AC ELECTRICAL GREASE PUMP VERSION 2 10 INTRODUCTION AND USER MANUAL ...

Страница 2: ...ill be increased INTRODUCTION ABOUT MANUFACTURER With over 25 years experience of manufacturing Centralized Lubrication Systems ALLFETT is able to provide a wide professional approach to select the correct Centralized Lubrication System for industry and heavy machinery A highly accurate manufacturing process is involved in producing Centralized Lubrication Systems in order that systems meet the ve...

Страница 3: ...IRECTION VALVE FUNCTIONAL DESCRIPTION LUBRICANT INFORMATION ELECTRICAL CONNECTIONS BUCKET BARREL CHANGE RULES TO COMPLY WHILE USING AND WARRANTY CONDITIONS PUMP MAINTENANCE ORDER INFORMATION WARRANTY WARRANTY CONDITIONS PAGE 1 PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 6 PAGE 7 PAGE 8 PAGE 9 PAGE 10 PAGE 11 PAGE 12 PAGE 13 PAGE 14 PAGE 15 ...

Страница 4: ...mp working principle is also variable to provide different requirements ALL 5 AC standard type pumps are controlled with pressure switch ALL 5 AC pumps can also work with by pass system PRODUCT DESCRIPTION GENERAL SPECIFICATIONS Working temperature 25 C 80 C Grease type NLGI 0 10 C 0 C NLGI 1 0 C 10 C NLGI 2 10 C 30 C Maximum pressure 380 V AC Motor type Motor protection class IP 54 200 bar Pump o...

Страница 5: ...DIMENSIONS Drawings in this page represents the ALL 5 two line AC pumps which is used with grease buckets Dimension unit is milimeter 365mm 310mm ALL 5 pump plunge length can be produced for optional bucket sizes Plunge length 458mm ...

Страница 6: ...which is used with grease buckets Optional specifications described seperately On Off switch Electrical box AC Motor Digital indicator Optional Dual line outlets Fuse Return line Return line Pressure line Bucket screws Follower piston Grease suction Bucket cover Direction valve Direction valve Manometer ...

Страница 7: ...ns to the units and the use of unouthorized spare parts and aids prohobited and disqualify the warranty Outlet couplings are not included with distributor and direction valve orders Outlet couplings must be ordered separately Digital indicator optional Line A Line B Pressure line P Return line R Direction change pressure adjustment screw Lock nut Digital indicator cable Optional Mechanical indicat...

Страница 8: ...ubrication line line A or Line B is complatelly filled with grease pressure will be increased When pressure reaches to the adjusted port direction pressure direction of the pressurized grease coming from pump is changed to other lubrication port According to dual line system working principle lubrication in distributor to lubrication point is occurs while other lubrication line is filled with grea...

Страница 9: ...een 10 C and 0 C for NLGI 1 grease recomended working temperature is between 0 C and 10 C for NLGI 2 grease recomended working temperature is between 10 C and 30 C Only LITHIUM based and EP additive liquid greases must be used with in system It is important that the grease will be used must resistant to high pressure Make sure the liquid grease you are using is EP additive ALL 5 pumps are designed...

Страница 10: ...ed spare parts and aids prohobited also disqualify the warranty Main electrical connection cable is coming into coupling placed under Electrical box Electrical connection Connection cabels are marked with numarators Please connect cables with appropriate energy as described below Fuse Electrical cable coupling Electrical box Main electrical cable Electrical connection pins 220 V AC connections 380...

Страница 11: ...n while moving pump forward and backward slowly This movement avoids the pump take air Tighten the cover screws again Pump is now ready to operate 1 2 3 4 5 ALL 5 pumps doesn t have reservoir 16 or 20 liters standard grease buckets or barrels are used as reservoir To avoid contamination of lubricant and trouble free usage grease bucket or barrel must be changed with new one when its empty Follow t...

Страница 12: ...damage and to ensure that they are firmly in place 5 Pumps have an electric driven motor Electrical lines must be connected properly by qualified and instructed personel 4 3 Washing of the pump with pressured water causes damage Any damage occur from this reason DISQUALIFIES THE WARANTY 2 Pumps are produced to lubrication purpose only and are not convenient to work more than 2 hours continuously W...

Страница 13: ...d Wait until working time starts If necessary control card pass to working period by pressing ADDITIONAL CYCLE button a b c d e Grease inside bucket or barrel is empty Chance the grease bucket or barrel according to items in page 16 Pump may take air due to work without grease To take air out from pump system remove the outlet coupling Start the pump and continue to operate pump until grease witho...

Страница 14: ...00 10 ZM 00 00 Order number Product name Order number Product name ALL 5 Two Line Bucket 220 V AC Ø12mm piston ALL 5 Two Line Bucket 220 V AC Ø16mm piston ALL 5 Two Line Bucket 220 V AC Ø20mm piston 10 22 16 D1 10 22 16 D2 10 22 16 D3 ALL 5 Two Line Bucket 380 V AC Ø12mm piston ALL 5 Two Line Bucket 380 V AC Ø16mm piston ALL 5 Two Line Bucket 380 V AC Ø20mm piston 11 38 16 D1 11 38 16 D2 11 38 16 ...

Страница 15: ...Y PRODUCER COMPANY FAX TELEPHONE CENTRAL ADRESS NAME ALLFETT Mekanik ve Elektronik Sistemler San ve Tic Ltd Þti 0212 501 33 37 0212 501 32 01 PBX Yeni Eyup Bulvari Topcular Cad Set Ustu No 1 Demirkapý Rami Ýstanbul AUTHORISED PERSON SIGNATURE STAMP PRODUCT TYPE Electrical grease pump BRAND ALLFETT MODEL SERIAL NUMBER DELIVERY DATE PLACE WARRANTY 2 years REPAIR TIME 30 days ALL 5 Standard ALL 5 Wit...

Страница 16: ...d expenses of any sort including labor the value of the parts replaced or any our charges The product will be replaced free of charge If the product permanently disfunctions due to repeating the same defect more than four times within the warranty period If the maximum period for repairing is exceeded If it is determined that the defect cannot be repaired by report written by the service or in the...

Страница 17: ... risk for environmental and human health during use TRANSPORT AND STORAGE There are no restrictions on transportation by land air and sea In general products should be stored in a dry and dust free environment The storage temperatures are between 10 C and 40 C All products are packed with paper based support matarial to reduce damage Upon receiving the package please check the items for possible d...