AOC P/N 033-0090
3
Rev.
10/99
VI.ASSIGNING MDS-EXPANDER™ II PRESETS TO AN ORGAN’S GENERAL
PISTONS
1. Select desired MDS-Expander™ II Preset group: (press PRESET, then UP or
DOWN.)
2. Press SET button on MDS-Expander™ II.
3. Press organ General piston to which MDS-Expander™ II Preset group
is to be assigned.
NOTE: On organs with a Console Controller , if you have accessed the “Program
Change Mode” and changed it to USER or NO, you must reset it to PRESET, otherwise
the SET function is disabled. See your Console Controller and MIDI Guide regarding
Program Change Mode.
VII. ASSIGNING MDS-EXPANDER™ II VOICES TO DIVISIONAL PISTONS
(WHERE
APPLICABLE)
1. Select the MDS-Expander™ II Division that corresponds to the organ’s
division: (Press DIV, then UP or DOWN)
2. Select desired MDS-Expander™ II Voice: (Press VOICE, then UP or
DOWN)
3.
Press
SET
button on MDS-Expander™ II.
4. Press organ’s Divisional Piston to which the MDS-Expander™ II voice is
to be remembered by.
VIII.
ACCESSING PRESETS 11 or higher
(FOR ALLEN ORGANS WITH CONSOLE CONTROLLER)
This subject is detailed in the “Console Controller and MIDI Guide” that is specific to any
particular Allen Organ. Please use that publication for this procedure.
NOTE:
Early version Console Controllers™ will return to Preset P-Change when the
organ’s power is shut off.
Newer version Console Controllers™ will retain the “U”, “P”, or “N” settings after
the organ’s power is turned OFF and then ON again.
IX. DISABLING AN MDS-EXPANDER™ II DIVISION
There are three ways to disable a single division of the MDS-Expander™ II, while still
accessing the other divisions.
1.
Turn off the associated organ MIDI coupler on the organ. This method is
acceptable when the MDS-Expander™ II is the only MIDI device connected to
the organ division in question. This will stop all MIDI information transmission
from that division.
2. Select MIDI OFF as a division's voice (See instructions for VOICE button above).
The organ will continue sending MIDI information to any other MIDI device in
use. The MDS-Expander™ II division will continue to respond to program
change information, including program change information sent by Allen organ’s
pistons.