Fault Codes
SPN
Code
FMI
Code
Fault Check Description
Fault Detection Condition
Possible
Causes
23614
0
Maximum Rail Pressure Exceeded
Maximum Rail
Pressure Exceeded
1
Maximum Rail Pressure Exceeded
(Second Stage)
Maximum Rail
Pressure Exceeded
(Second Stage)
20
Maximum Positive Deviation of Rail
Pressure Exceeded
Maximum Positive
Deviation of Rail
Pressure Exceeded
22
Maximum Negative Rail Pressure
Deviation with Closed Pressure Control
Valve Exceeded
Maximum negative
Rail Pressure De-
viation with Closed
Pressure Control
Valve Exceeded
23895
13
Check of Missing injector Adjustment
Value Programming
D
etection if the monitoring for missing or faulty programming of the
injector adjustment values is active and:
• the checksum of the injector adjustment code words is not correct
or
• the basic correction quantity in at least one injector checkpoint has
exceeded the admissible limits
or
• no injector adjustment values could be read due to faulty EEPROM
access.
IMA not pro-
grammed
23896
13
Check Of Missing Injector Adjustment
Value Programming
IMA Not Pro-
grammed
23897
13
23898
13
23906
3
Short Circuit to Battery of Pre-Supply
Pump Output
Wiring Harness or
Component
4
Short Circuit to Ground of Pre-Supply
Pump Output
5
Open Load of Pre-Supply Pump Output
Wiring harness or
Component
12
Over Temperature Error on ECU
Powerstage for Pre-Supply Pump
ECU Internal Fault
24000
0
Error Path SPN1 Matching of DM1DCU
Message
The error is set in this DFC if received SPN number match with Com_
numDM1DCUSPN1_CA
CAN Transmitter
11
Function Monitoring: Fault in the
Monitoring of the Start Control
ECU Internal Fault
SECTION 3
SERVICE
069970
Page 53
Содержание 068360
Страница 12: ...SECTION 1 SAFETY SECTION 1 SAFETY 069970 Page 12 ...
Страница 25: ...SECTION 2 OPERATION SECTION 2 OPERATIONS 069970 Page 25 ...
Страница 37: ...SECTION 3 SERVICE 069970 Page 37 SECTION 3 SERVICE ...
Страница 55: ...SECTION 4 ACCESSORIES SECTION 4 ACCESSORIES 069970 Page 55 ...
Страница 59: ...069970 Page 59 ...