Fault Codes
SPN
Code
FMI
Code
Fault Check Description
Fault Detection Condition
Possible
Causes
20290
3
Diagnostic Fault Check to Report the
Error in Over-Voltage Monitoring
Irreversible error bit 2 set in MoCSOP_st ( counter MoCSOP_ctDebPSDia
>= MoCSOP_ctDebPSDia_C (2 Events) during over voltage detection of
the SOP test).
ECU Internal Fault
11
Loss of Synchronization Sending Bytes
to the MM from CPU
Irreversible error bit 5 set in MoCSOP_st (counter MoCSOP_ctErrMMRe-
spByte > MOCSOP_MM_RESPBYTE_RESET_ERROR(10) within the SOP
test) and state MOCSOP_STEP_ERROR reached due to time out.
20
DFC to set a Torque Limitation once an
Error in Detected Before MoCSOP's Error
Reaction is set
If an error was found by the SOP test but additionally the injector diag-
nose reported an error (FId_Mo-CSOPInjDiagErr or FId_MoCSOPInjDiag-
Deb are blocking) then only the test flag of every MoCSOP DFC will be
set. Besides the error bits of DFC_MoCSOPErrNoChk will be set.
21
Wrong Set Response Time
Irreversible error bit 8 set in MoCSOP_st ( counter MoCSOP_ctErrResp-
Time > MOCSOP_MM_RESPTIME_RESET_ERRORS(2) within the SOP
test) and state MOCSOP_STEP_ERROR reached due to time out.
22
Too Many SPI Errors During CoCSOP
Execution
Irreversible error bit 6 set in MoCSOP_st (counter MoCSOP_ctErrSPI
>= MOCSOP_SPI_RESET_ERRORS(16) within the SOP test) and state
MOCSOP_STEP_ERROR reached due to time out.
23
Diagnostic Fault Check to Report the
Error in Under-voltage Monitoring
Irreversible error bit 3 set in MoCSOP_st ( counter MoCSOP_ctDebPSDia
>= MoCSOP_ctDebPSDia_C during under voltage detection of the SOP
test).
Diagnostic Fault Check to Report that
WDA is not working correct
Irreversible error bit 1 set in MoCSOP_st (for example counter MoCSOP_
ctDebSOPTst >= MoCSOP_ctDebSOPTst_C (66 Events) or (MoCSOP_ct-
DebPSDia < MoCSOP_ctDebPSDia_C (2 Events)) AND (MoCSOP_ctCyl-
Num >= MoFInjDat_numCyl_C (4) ) during the MM SOP test).
25
OS Timeout in the Shut Off Path Test.
Failure Setting the Alarm Task Period
Irreversible error bit 7 set in MoCSOP_st (counter MoCSOP_ctErrOSTim-
eout > MOCSOP_MM_OSTIMEOUT_RESET_ERRORS(2) within the SOP
test) and state MOCSOP_STEP_ERROR reached due to time out.
Diagnostic Fault Check to Report that
the Positive Test Failed
Irreversible error bit 10 set in MoCSOP_st (bit MOCSOP_RSLTRDY_BP(0)
of the return value from InjVlv_SOPTst() set to one, and bit MOCSOP_
SUCCESS_BP(1) set to zero).
Diagnostic Fault Check to Report the
Timeout in the Shut Off Path Test
Irreversible error bit 0 set in MoCSOP_st ( counter MoCSOP_ctDebSOPT-
st > MoCSOP_ctDebSOPTst_C (66 Events) during SOP test).
22040
19
Timeout Error on CAN-Receive-Frame
TSC1TE
Timeout of TSC1_TE message.
The message is not received for 40 ms (TimeoutCount = 4, selected
task cycle = 10 ms, FRMSCH_RXMODE1) and the defect debouncing
time DDRC_DurDeb.Com_tiTSC1TETODebDef_C is passed and the TSC1
message is enabled and there is no busoff (i.e Com_stSAEJ1939RxEn-
bl[12].6 is set to 1)
CAN Transmitter
DPF System
22058
19
Reported SPI and COM-Errors of a
Cy146
ECU Internal Fault
23350
4
Short Circuit
Short circuit in injection bank 0
(all injectors of the same bank can be affected)
Wiring Harness
or Injector Short
Circuit
23352
4
Short Circuit
Short circuit in injection bank 1
(all injectors of the same bank can be affected)
23354
12
CY33X is Defect
Chip Error in the CY33x Power Stage Component
ECU Internal Fault
23550
12
Defective T50 Switch
The debounced signal is high (T50_st == 1) for a period longer than
DDRC_DurDeb.T50_tiErrDebDef_C (50ms)
Switch Defective
or is Active for a
Long time
SECTION 3
SERVICE
069970
Page 51
Содержание 068360
Страница 12: ...SECTION 1 SAFETY SECTION 1 SAFETY 069970 Page 12 ...
Страница 25: ...SECTION 2 OPERATION SECTION 2 OPERATIONS 069970 Page 25 ...
Страница 37: ...SECTION 3 SERVICE 069970 Page 37 SECTION 3 SERVICE ...
Страница 55: ...SECTION 4 ACCESSORIES SECTION 4 ACCESSORIES 069970 Page 55 ...
Страница 59: ...069970 Page 59 ...