Ultra1500 Digital Drives Quick Start 13
Publication 2092-QS001D-EN-P — July 2005
Drive Specifications
Drive 2092-DA1
2092-DA2
2092-DA3
2092-DA4
2092-DA5
Weight
0.9 kg (1.98 lbs)
1.2 kg (2.65 lbs)
2.1 kg (4.63 lbs)
Temperature
0° C to 50° C (32° F to 122° F)
Operating Shock,
and Vibration
15 G, Half Sine, 11 ms
5 – 500 Hz @ 2.5 G, 0.381 mm (0.015 in.) maximum displacement
Short Circuit Current Rating with
No Fuse Restrictions
Suitable for use on a circuit capable of delivering not more than 5000 rms
symmetrical amperes, 240 Volts maximum.
Short Circuit Current Rating with
Fuse Restrictions
Suitable for use on a circuit capable of delivering not more than 200,000 rms
symmetrical amperes, 240 Volts maximum, when protected by high interrupt
capacity, current limiting fuses UL198C (Class CC, G, J, L, R, T).
Motor Overload Protection
Utilizes solid state motor overload protection which operates:
•
within 8 minutes at 200% overload.
•
within 20 seconds at 600% overload
Symbols Used on Drive
Protective ground conductor terminal
Certification and Compliance
1
UL
®
listed to U.S. and Canadian safety standards (UL 508C File E145959)
CE and C-Tick marked for all applicable directives
Main Input Power
Nominal Input Voltage (V
rms)
2,3
200-240V, 1 phase, 50 or 60 Hz
200- 240V, 3 phase, 50 or 60 Hz
Input Current (A
rms
)
3.3A 5.5A 8.0A 11.0A 15.0A
Maximum Inrush Current (0-peak)
200A
Maximum Power Cycles/Minute
1 power cycle/2 minute interval
DC Bus Discharge Time
3 minutes after removal of main AC power
Control Input Power
Input Voltage (V
rms
)
2,3
200-240V, 1 phase, 50/60 Hz
Input Current (A
rms
)
2.0A
Maximum Inrush Current (0-peak)
75A
Motor Output
Continuous Output Current (0-peak)
1.4A 2.4A 4.7A 10.7A 16.4A
Intermittent Output Current (0-peak)
3.4A 7.2A 11.3A
24.8A
43.4A
Continuous Output Power @ 240V
ac
400W 650W 1000W 3000W 4000W
Power Dissipation
Maximum Power Dissipation
4
100W+50W
4
150W+70W
4
1 Refer to
www.ab.com/certification/ce/doc
for more information.
2 Nominal values are listed. Absolute range is 180 to 264 V
rms
.
3 The AC input voltage between any two input power pins (L1, L2, L3, L1C, L2C, and CHASSIS) must not exceed this rating. This note also applies to the
CHASSIS ground connection, which implies that transformer secondaries must be grounded.
4 Maximum Power Dissipation includes dissipative power of drive plus the Continuous Shunt Power rating of the drive’s internal shunt.