Allen-Bradley POINT I/O series Скачать руководство пользователя страница 4

4

    POINT I/O 2 and 4 Relay Output Modules 

Publication 1734-IN055H-EN-E - August 2016

North American Hazardous Location Approval

The following information applies when 
operating this equipment in hazardous 
locations:

Informations sur l’utilisation de cet équipement 
en environnements dangereux:

Products marked “CL I, DIV 2, GP A, B, C, D” are 
suitable for use in Class I Division 2 Groups A, B, 
C, D, Hazardous Locations and nonhazardous 
locations only. Each product is supplied with 
markings on the rating nameplate indicating the 
hazardous location temperature code. When 
combining products within a system, the most 
adverse temperature code (lowest “T” number) 
may be used to help determine the overall 
temperature code of the system. Combinations 
of equipment in your system are subject to 
investigation by the local Authority Having 
Jurisdiction at the time of installation.

Les produits marqués “CL I, DIV 2, GP A, B, C, D” ne 
conviennent qu'à une utilisation en environnements de 
Classe I Division 2 Groupes A, B, C, D dangereux et non 
dangereux. Chaque produit est livré avec des 
marquages sur sa plaque d'identification qui indiquent 
le code de température pour les environnements 
dangereux. Lorsque plusieurs produits sont combinés 
dans un système, le code de température le plus 
défavorable (code de température le plus faible) peut 
être utilisé pour déterminer le code de température 
global du système. Les combinaisons d'équipements 
dans le système sont sujettes à inspection par les 
autorités locales qualifiées au moment de 
l'installation.

EXPLOSION HAZARD

• Do not disconnect equipment 

unless power has been removed 
or the area is known to be 
nonhazardous. 

• Do not disconnect connections to 

this equipment unless power has 
been removed or the area is 
known to be nonhazardous. 
Secure any external connections 
that mate to this equipment by 
using screws, sliding latches, 
threaded connectors, or other 
means provided with this product.

• Substitution of components may 

impair suitability for Class I, 
Division 2.

• If this product contains batteries, 

they must only be changed in an 
area known to be nonhazardous.

RISQUE D’EXPLOSION

• Couper le courant ou s'assurer que 

l'environnement est classé non 
dangereux avant de débrancher 
l'équipement.

• Couper le courant ou s'assurer que 

l'environnement est classé non 
dangereux avant de débrancher les 
connecteurs. Fixer tous les 
connecteurs externes reliés à cet 
équipement à l'aide de vis, loquets 
coulissants, connecteurs filetés ou 
autres moyens fournis avec ce produit.

• La substitution de composants peut 

rendre cet équipement inadapté à une 
utilisation en environnement de 
Classe I, Division 2.

• S'assurer que l'environnement est 

classé non dangereux avant de 
changer les piles.

WARNING: 

Exposure to some chemicals may degrade the sealing properties of 

materials used in the following devices:

Relay K2 and K4, Epoxy for 1734-OW2, and Relay K1 through K4, Epoxy 

 

for 1734-OW4.

It is recommended that the User periodically inspect these devices for any 
degradation of properties and replace the module if degradation is found.

Содержание POINT I/O series

Страница 1: ...onment and Enclosure 3 Preventing Electrostatic Discharge 3 North American Hazardous Location Approval 4 European Hazardous Location Approval 5 About the Module 6 Mount the I O Base 8 Install the Modu...

Страница 2: ...installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect...

Страница 3: ...or minimize the spread of flame complying with a flame spread rating of 5VA or be approved for the application if nonmetallic The interior of the enclosure must be accessible only by the use of a too...

Страница 4: ...ts dans le syst me sont sujettes inspection par les autorit s locales qualifi es au moment de l installation EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is k...

Страница 5: ...an environment of not more than Pollution Degree 2 as defined in IEC 60664 1 when applied in Zone 2 environments The enclosure must utilize a tool removable cover or door WARNING This equipment shall...

Страница 6: ...les The wiring base assembly consists of a mounting base 1734 MB and removable terminal block 1734 RTB or 1734 RTBS and 1734 TOP or 1734 TOPS one piece terminal base Modules Mounted on Removable Termi...

Страница 7: ...4 TOPS One piece Terminal Base Description Description 1 Module locking mechanism 5 Interlocking side pieces 2 Slide in writable label 6 Mechanical keying 3 Handle 7 DIN rail locking screw orange 4 17...

Страница 8: ...g side pieces to engage the adjacent module or adapter 3 Press firmly to seat the mounting base on the DIN rail The mounting base snaps into place ATTENTION This product is grounded through the DIN ra...

Страница 9: ...the number required for the type of module being installed aligns with the notch in the base 2 Make certain the DIN rail locking screw is in the horizontal position You cannot insert the module if th...

Страница 10: ...2016 3 Insert the module straight down into the mounting base and press to secure The module locks into place Turn the keyswitch to align the number with the notch Notch position 3 is shown Make sure...

Страница 11: ...utput Modules 11 Publication 1734 IN055H EN E August 2016 Turn the keyswitch to align the number with the notch Notch position 1 is shown Make sure the DIN rail locking screw is in the horizontal posi...

Страница 12: ...e wiring base 2 Rotate the terminal block into the wiring base until it locks itself in place 3 If an I O module is installed snap the RTB handle into place on the module WARNING When you connect or d...

Страница 13: ...mm diameter blade into the opening at approximately 73 blade surface is parallel with top surface of the opening and push up gently WARNING For 1734 TOPS and 1734 TOP3S to latch and un latch the wire...

Страница 14: ...right 6 Use a small bladed screwdriver to rotate the orange base locking screw to a vertical position This releases the locking mechanism 7 Lift straight up to remove Communicate with Your Module I O...

Страница 15: ...ure that power is removed or the area is nonhazardous before proceeding Relay Output Module Status Network Status 1734 OW4 NODE 0 1 2 3 Relay Output Module Status Network Status 1734 OW2 0 1 NODE Modu...

Страница 16: ...Powered by External Power Bus Load power must be provided by an external power source for the 1734 OW4 The 1734 OW4 cannot be powered from the internal power bus Channel Output Channel Output 0A 0 2A...

Страница 17: ...l The slightest variation in relay switching time may cause one relay to momentarily switch the total load current ATTENTION Make sure that all relay wiring is properly connected before applying any p...

Страница 18: ...4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 PDN IB2 IB4 IV2 IV4 FPD OW2 AC power bus C V L2 N L1 45187 OW2 OW2 0 1 0 1 0 1 0...

Страница 19: ...diagram and table for information on how to interpret the status indicators Relay Output Module Status Network Status 1734 OW4 NODE 0 1 2 3 Relay Output Module Status Network Status 1734 OW2 0 1 NODE...

Страница 20: ...us Off Device is not online Device has not completed dup_MAC id test Device not powered check module status indicator Flashing green Device is online but has no connections in the established state Gr...

Страница 21: ...ximum rating at voltages between the maximum design value and 120V the maximum make and break ratings are to be obtained by dividing the volt amperes rating by the application voltage For voltages bel...

Страница 22: ...ckaged Damp Heat 5 95 noncondensing Vibration IEC 60068 2 6 Test Fc Operating 5 g 10 500 Hz Shock operating IEC 60068 2 27 Test Ea Unpackaged Shock 30 g Shock nonoperating IEC 60068 2 27 Test Ea Unpac...

Страница 23: ...opean Union 2014 35 EU LVD compliant with EN 61131 2 Programmable Controllers Clause 11 Ex European Union 2014 34 EU ATEX Directive compliant with EN 60079 15 2010 Potentially Explosive Atmospheres Pr...

Страница 24: ...s to be returned follow these procedures Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete th...

Отзывы: