background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Содержание Flex integra 1793-IB16

Страница 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Страница 2: ... with FLEX I O modules do not mount between FLEX I O modules Mount Integra modules to the right of the FLEX I O modules To mount this module 1 Remove the cover plug if used in the male connector of the unit to which you are connecting this module 2 Position the module on the 35 x 7 5mm DIN rail A A B pt no 199 DR1 3 Rotate the module onto the DIN rail with the top of the rail hooked under the lip ...

Страница 3: ...erminal base until the units lock together 6 Repeat the above steps to install the next module 7 To remove an Integra module you must work from the right side and remove one module at a time To disengage a module from its neighbor place a common flat bladed screwdriver between the 2 modules and turn 1 4 turn to separate the modules 8 Then slide the module away from its left neighbor and release th...

Страница 4: ... safety requirements of EN 61131 2 Programmable Controllers Part 2 Equipment Requirements and Tests For specific information required by EN 61131 2 see the appropriate sections in this publication as well as the following Allen Bradley publications Industrial Automation Wiring and Grounding Guidelines For Noise Immunity publication 1770 4 1 Automation Systems Catalog publication B111 This equipmen...

Страница 5: ...from terminal V to terminal 8 on the next 8 point Integra module or terminal V on the next 16 point Integra module 6 If daisy chaining 24V dc common from this module to the next FLEX Integra module connect a jumper from terminal COM on this module to terminal 0 on the next 8 point Integra module or to terminal COM on the next 16 point Integra module ATTENTION Total current draw through the module ...

Страница 6: ...rresponding terminal on row B 1 1 9 9 2 2 10 10 3 3 11 11 4 4 12 12 5 5 13 13 6 6 14 14 7 7 15 15 24V dc Power terminals V are internally connected together in the module 24V dc common Common terminals COM are internally connected together in the module A B 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 COM COM V V 41818 2 Wire Sensor 3 Wire Sensor Artisan Technology Group Quality Instrumentation Guarantee...

Страница 7: ...ations Memory Mapping Bit Word 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00 Read I15 I14 I13 I12 I11 I10 I9 I8 I7 I6 I5 I4 I3 I2 I1 I0 Write Reserved DT 12 15 DT 00 11 Where I Input DT delay time refer to Setting the Input Delay Time 1793 IB16 A B 0 1 2 3 4 5 6 7 8 9 10 11 14 15 12 13 24 VDC SINK INPUT 41812 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg...

Страница 8: ... Division 2 wiring methods and in accordance with the authority having jurisdiction 02 01 00 Filter Time for Inputs 00 11 Selected Filter Time 05 04 03 Filter Time for Inputs 12 15 0 0 0 Filter Time 0 default 250μs 0 0 1 Filter Time 1 500μs 0 1 0 Filter Time 2 1ms 0 1 1 Filter Time 3 2ms 1 0 0 Filter Time 4 4ms 1 0 1 Filter Time 5 8ms 1 1 0 Filter Time 6 16ms 1 1 1 Filter Time 7 32ms 15 14 13 12 1...

Страница 9: ...ntes font partie intégrante de la documentation des produits de commande industrielle certifiés Cet équipement ne convient qu à une utilisation dans des environnements de Classe I Division 2 Groupes A B C D ou non dangereux Les produits portant le marquage C UL and UL approprié c est à dire Classe I Division 2 Groupes A B C D sont certifiés pour une utilisation avec d autres équipements les combin...

Страница 10: ...azardous 9 57 66 0 17 5LVTXH G H SORVLRQ La substitution de composants peut rendre ce matériel inadapté à une utilisation en environnement de Classe I Division 2 Couper le courant ou s assurer que l environnement est classé non dangereux avant de remplacer des composants Couper le courant ou s assurer que l environnement est classé non dangereux avant de débrancher l équipement Couper le courant o...

Страница 11: ...μs 1ms 2ms 4ms 8ms 16ms or 32ms 250μs 500μs 1ms 2ms 4ms 8ms 16ms or 32ms Default 250μs selectable thru output image table Flexbus Current 25mA maximum Power Dissipation 6 1W 31 2V dc Thermal Dissipation 20 8 BTU hr 31 2V dc Indicators 16 yellow channel status indicators External dc Power Voltage 19 2 31 2V dc 5 ac ripple See Derating Curve Dimensions Inches Millimeters 2 72H x 3 7D x 3 2W 69H x 94...

Страница 12: ... applicable directives C Tick marked for all applicable acts 1Use this category information for planning conductor routing as described in publication 1770 4 1 Wiring and Grounding Guidelines for Noise Immunity Specifications 16 Input Module Cat No 1793 IB16 and IB16S 31 2 30 25 20 15 10 0 10 20 30 40 50 55 60 37 27 5 Vin On State Voltage V dc 41820 Ambient Temperature o C Artisan Technology Group...

Страница 13: ... December 1999 PN 957259 15 Supersedes publication 1793 5 8 September 1999 1999 Rockwell International Corporation Printed in USA Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Страница 14: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Отзывы: