Chapter
6
Publication 1794-6.5.16 – September 1998
Input, Output and
Configuration Files for Analog
Modules when used with
ControlNet
In this chapter you will learn about:
•
ControlNet Adapter
•
I/O structure
•
safe state data
•
communication fault data
•
idle state behavior
•
input data behavior upon module removal
The FLEX I/O ControlNet adapters (cat. no. 1794–ACN15 and
–ACNR15) interfaces up to 8 FLEX I/O modules and a ControlNet
processor or scanner. The adapter can support ControlNet real–time
data connections to individual modules or module groups. Each
connection is independent of the others and can be from different
processors or scanners.
One 1794-ACN15 and -ACNR15 ControlNet adapter can interface
up to eight terminal base units with installed FLEX I/O modules,
forming a FLEX I/O system of up to eight slots. The adapter
communicates to other network system components (typically one or
more controllers or scanners, and/or programming terminals) over
the ControlNet network. The adapter communicates with its I/O
modules over the backplane.
Inputs
Status
Outputs
Configuration
Slot 0
I/O Module
Read
Words
Write
Words
0
15
Read
Write
ControlNet
Adapter
Inputs
Status
Outputs
Configuration
Slot 1
I/O Module
Inputs
Status
Outputs
Configuration
Slot 7
I/O Module
Network
Data is exchanged scheduled (when mapped) or unscheduled (using
CIO instructions).
Chapter Objectives
About the ControlNet
Adapter
Communication Over the
FLEX I/O Backplane
Allen-Bradley HMIs
Содержание FLEX I/O 1794-IP4
Страница 1: ...User Manual FLEX I O 4 Input Pulse Counter Module Cat No 1794 IP4 Allen Bradley Allen Bradley HMIs...
Страница 6: ...Using This Manual P 4 Publication 1794 6 5 16 September 1998...
Страница 10: ...Table of Contents iv Publication 1794 6 5 16 September 1998...
Страница 62: ...7 2 Troubleshoot the Pulse Counter Module Publication 1794 6 5 16 September 1998...