Installation Instructions

Original Instructions

FLEX 5000 Terminal Base Assembly Modules

Catalog Numbers Terminal Bases Assemblies: 5094-TB3, 5094-TB3S, 5094-TB3XT, 5094-TB3SXT, 5094-TB3T, 5094-TB3TS, 5094-TB3TXT, 
5094-TB3TSXT, 5094-TB3W, 5094-TB3WS, 5094-TB3WXT, 5094-TB3WSXT

Mounting Bases: 5094-MB, 5094-MBXT

Removable Terminal Blocks: 5094-RTB3, 5094-RTB3XT, 5094-RTB3S, 5094-RTB3SXT, 5094-RTB3T, 5094-RTB3TXT, 5094-RTB3TS, 5094-
RTB3TSXT, 5094-RTB3W, 5094-RTB3WXT, 5094-RTB3WS, 5094-RTB3WSXT

Product Overview

The FLEX 5000 terminal base assemblies comprise of either a 5094-MB or a 5094-MBXT and one of the removable terminal blocks needed as a 
terminal base for your specific FLEX 5000 I/O modules. Terminal base assemblies are a required part of the FLEX™ 5000 I/O system.

FLEX 5000 I/O systems are used with some Logix5000™ controllers and configured with the Studio 5000 Logix Designer® application. For more 
information on how which Logix5000 controllers and Logix Designer application versions are compatible with FLEX 5000 I/O modules, see the 
publications listed in 

Additional Resources on page 15

.

Topic Page

About the Terminal Base Assemblies

5

Before You Begin

6

Required Components

6

Mount the Terminal Base on a DIN Rail

9

Wire the Terminal Base

11

Disconnect Wires from the Terminal Base

12

Typical Wiring Guidelines

13

Terminal Base Assembly Specifications

14

Additional Resources

15

Содержание FLEX 5000

Страница 1: ...ovable terminal blocks needed as a terminal base for your specific FLEX 5000 I O modules Terminal base assemblies are a required part of the FLEX 5000 I O system FLEX 5000 I O systems are used with so...

Страница 2: ...cati nella sezione Altre risorse riguardanti l installazione la configurazione ed il funzionamento dell apparecchiatura Gli utenti devono leggere e comprendere le istruzioni di installazione e cablagg...

Страница 3: ...s dangereux Lorsque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp ratur...

Страница 4: ...andle this equipment Touch a grounded object to discharge potential static Wear an approved grounding wriststrap Do not touch connectors or pins on component boards Do not touch circuit components ins...

Страница 5: ...XT 5094 RTB3S 5094 RTB3SXT RTB MB FRONT VIEW Backplane connector DIN rail mount System connector Threaded insert for RTB captive fastener DIN rail actuator RTB locking pegs FRONT VIEW Keyswitches set...

Страница 6: ...0 I O modules MB type depends on your system requirements Refer to FLEX 5000 I O Modules Specifications Technical Data publication 5094 TD001 for system requirements Removable terminal block RTB type...

Страница 7: ...tion see the publications that are listed in Additional Resources on page 15 Tools The following tools are needed screw driver such as the 1492 N90 terminal block screw driver with hardened 3mm diamet...

Страница 8: ...shield bar to the bottom row of terminals on the 5094 RTB3 or the 5094 RTB3T 1 Insert the mounting hooks of the shield bar into the holes under the last row of terminals on the RTB 2 Pivot the shield...

Страница 9: ...urely mounted You can use an Allen Bradley 199 DR1 46277 3 EN50022 35 x 7 5 mm 1 38 x 0 30 in DIN rail with a FLEX 5000 I O system RemoveorReplaceOptionalSAPowerJumpersfromTerminalBases 1 Unscrew term...

Страница 10: ...e 8 RemoveorReplacetheTerminalBase 1 If there is an I O module installed remove the I O module from the terminal base 2 Turn the DIN rail actuator to the unlocked position 3 Carefully pull the termina...

Страница 11: ...dividual I O module installation instructions 5 Connect V DC power to terminal SA 6 Connect V DC common to terminal SA WARNING If you connect or disconnect wiring while the field side power is on an e...

Страница 12: ...terminal base WARNING If you connect or disconnect wiring while power is applied an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is rem...

Страница 13: ...nalog Output Module Specialty Module Counter Module Modules with total SA loading 10 A Modules with total SA loading 10 A Modules with total SA loading 10 A Modules with total SA loading 80 of SA 5094...

Страница 14: ...allation instructions for your specific I O module Insulation stripping length Screw 0 34 2 5 mm2 22 14 AWG 12 mm 1 mm 0 47 in 0 04 in Spring 0 34 1 3 mm2 22 16 AWG 10 mm 1 mm 0 39 in 0 04 in 2 5 mm2...

Страница 15: ...cing Output Modules Installation Instructions publication 5094 IN004 Provides information on how to install FLEX 5000 digital output I O modules FLEX 5000 Digital 8 point Isolated Relay Output Module...

Страница 16: ...needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at http literature rockwellautomation com idc groups literature documents du ra du002_ en e...

Отзывы: