Allen-Bradley Bulletin 1609 Скачать руководство пользователя страница 1

Installation Instructions

(Cat 1609-B)

Bulletin 1609 Industrial Uninterruptible Power Supply

ATTENTION: 

Please read and save these instructions.  This manual contains important instructions for the Bulletin 1609 Uninterrupt-

ible Power Supply.  Follow these instructions during the unpacking, installation and maintenance of the UPS.  If you have a problem 
with the UPS, please refer to this manual and the User Manual trouble shooting section before calling Technical Services.

Contents for UPS Include:

• Installation Instruction

•1609-B

•USB Cable

•CD

•1 Battery Jumper Wire (inside the battery compartment)

•Battery Harness (inside the battery compartment)

Additional Resources

1.

  Go to 

 http://www.rockwellautomation.com/literature

2.  

Go to 

Search

,

 select 

Publication Number

.

3.  

Type the 

Publication Number

 in the search box and press enter.     

1609-IN014 

(1609-SPD Installation Instructions)

1609-UM007 

(1609 UPS Management Software User Manual)   

1609-UM009 

(1609 UPS User Manual) 

Install the 1609 UPS in the Appropriate Environment 

Do not operate the UPS where there is excessi

v

e dust or the temperature or humidity is outside the 

speci

fi

ed limits.  The maximum ambient temperature is 40 degree Celsius using the 1609-SBAT or 50 degree 

Celsius using the 1609-HBAT.   The maximum  humidity specification is 95% RH (Non-condensing).

Note:

  Batteries are not included with the UPS.

Содержание Bulletin 1609

Страница 1: ...the battery compartment Battery Harness inside the battery compartment Additional Resources 1 Go to http www rockwellautomation com literature 2 Go to Search select Publication Number 3 Type the Publ...

Страница 2: ...a at surface Use the provided jumper wire to connect the batteries in series Connect the positive terminal red of the battery to the negative terminal black of another battery Connect the red wire of...

Страница 3: ...e Diagram 2 below Diagram 1 Standard DIN Rail Mount Diagram 2 Optional Panel or Floor Mount Batteries Wiring and Installation Instruction for the UPS Cont d 5 To complete the battery installation clos...

Страница 4: ...Minimum temperature 75 C Wire conductor material Copper only Tightening torque for terminals 4 4 lb in Warning To reduce the risk of fire connect only to a circuit provided with 20 amperes maximum bra...

Страница 5: ...a Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from the batteries b When replacing ba...

Страница 6: ...software is stored in the CD and can be found in the accessory bag Manual or Remote Enable Disable of UPS Output Selection The 1609 B UPS output is designed to be manually or remotely Enabled or Disab...

Страница 7: ...Version 01 L E N L E AC Input AC Output Backfeed Relay Inverter Relay AC to DC Charger DC to DC DC to AC Step Wave Backfeed Relay Input Filter N Indicator LED Indicator Title On Line The UPS is supply...

Страница 8: ...Styrofoam beads for packaging Damage sustained in transit is not covered under warranty DIR 10000234490 Version 01 Copyright 2012 Rockwell Automation Inc All Rights Reserved Printed in China Allen Br...