Remote Monitoring for PowerFlex 755 AC Drive

Status Indicator Descriptions

Status Indicator

Color

Indication

Possible Action

RS485/RS232

OFF

Port disabled

Steady red

Port failure

Contact support

Steady green

Port enabled from Netbiter Argos

Uplink/WAN

Steady green

Connected to Netbiter Argos

Steady red

Incorrect IP settings

Dynamic IP Address - check for DHCP server on network
Fixed IP Address - check the settings for IP Address, gateway and DNS servers

Updating red

Unable to connect to Internet/Netbiter Argos

Check network settings and firewalls

Modem (EC350 only)

OFF

Modem disabled

Steady red

Modem failure

Contact support

Updating red

SIM card failure

Check that the SIM card is correctly inserted and not damaged

Steady orange

PIN code enabled on SIM card

Disable PIN code on the SIM card

Updating orange

No APN server specified

The APN (Access Point Name) Server must be set from Netbiter Argos

Steady green

Modem registered on mobile network

Updating green

Modem is searching for mobile network

Gateway

OFF

Unit has no power, or is starting up

Steady green

Normal operation

Updating green

Firmware update in progress

Steady red

Hardware failure - contact support

Updating red

Application failure - contact support

Power

OFF

No power

Steady green

Unit has power

Ethernet Link
(located on RJ45 ports)

OFF

No network detected

Orange flicker

Activity on 10 Mbps Ethernet network

Green flicker

Activity on 100 Mbps Ethernet network

Specifications

Attribute

Value

Mobile Communication (EC350 
only)

5-band 3G/UMTS (WCDMA/FDD): 800, 850, 1900, AWS, 2100 MHz
Quad-band GSM/GPRS: 850, 900, 1800, 1900 MHz

Antenna Connector
(EC350 only)

Mobile:

 SMA female

USB Interface

Micro USB, USB 2.0

Mounting

DIN rail (EN 50022) and wall mounting

Dimensions (H x W x D)

1 x 5.3 x 3.6 in. (25.6 x 135 x 92 mm)

Temperature

Operating:

 -40…149 °F (-40…65 °C)

Storage:

 -49…185 °F (-45…85 °C)

Humidity Range

5…95% RH, noncondensing

Power Supply

12…48V DC

Power Consumption

EC310:

 2.5 W

EC350:

 4.5 W

Certifications

EC310:

 CE, ROHS

EC350:

 CE, ROHS, Telec, JATE

To check the mobile signal strength on EC350:
Press and release the Mode button.

 The top 5 statud indicators will now show the signal strength:

1 updating red: No/unknown signal

1 updating orange: Poor signal

1 updating green: OK signal

2…5 updating green: Good to optimum signal

The status indicators will automatically return to showing the standard after 60 
seconds.

Содержание 9300-VSELV

Страница 1: ...Instructions Remote Monitoring for PowerFlex 755 AC Drive Catalog Numbers 9300 VSELV and9300 VSELVCELL Topic Page Remote Monitoring Kit 3 Field Mounting Instructions 3 Connection Instructions 4 Apply Power 6 Verify Internet Connection 6 ...

Страница 2: ... code de pratique en vigueur Si cet équipement est utilisé d une façon qui n a pas été définie par le fabricant la protection fournie par l équipement peut être compromise 주의 본 제품 설치 설정 작동 또는 유지 보수하기 전에 본 문서를 포함하여 설치 설정 및 작동에 관한 참고 자료 섹션의 문서들을 반드시 읽고 숙지하 십시오 사용자는 모든 관련 규정 법규 및 표준에서 요구하는 사항에 대해 반드시 설치 및 배선 지침을 숙지해야 합니다 설치 조정 가동 사용 조립 분해 유지보수 등 모든 작업은 관련 규정에 따라 적절한 교육을 받은 사용자를 통해서만 수행해야 합니다 본 장비를 제조...

Страница 3: ...manual FieldMountingInstructions Use the following information to install the included hardware to enable the Remote Monitoring service GatewayMounting The Netbiter gateway hardware is a DIN rail Type EN50022 mounted device with dimensions H x W x D of 1 01 x 5 31 x 3 62 in 25 6 x 135 x 92 mm The mounting space on the DIN rail must be large enough to accommodate the size of the gateway plus an add...

Страница 4: ...lling a Netbiter EC310 the Ethernet WAN port connects to the enterprise Internet network Your Internet firewall is required to allow a Port 443 outbound connection to https www ramonitoring com and xx netbiter net the xx indicating the complete range Access to a domain name system DNS server is also required The WAN port is not used for the Netbiter EC350 If installing the Netbiter EC350 connect t...

Страница 5: ...ssibleLANTopologies IMPORTANT WheninstallingaNetbiter EC310 theEthernet WANport connects to your internet network Yourinternet firewallis requiredtoallow aPort 443outbound connection to https www ramonitoring com and xx netbiter net the xx indicating the complete range Access to a domain name system DNS server is also required ...

Страница 6: ...e Monitoring for PowerFlex 755 AC Drive ApplyPower The Netbiter EC310 EC350 devices require a 12 48V DC power source to be powered on Connect the Netbiter to the power source as described in the schematic below EC310 EC350PowerandGroundWiring VerifyInternetConnection ...

Страница 7: ...ting up Steady green Normal operation Updating green Firmware update in progress Steady red Hardware failure contact support Updating red Application failure contact support Power OFF No power Steady green Unit has power Ethernet Link located on RJ45 ports OFF No network detected Orange flicker Activity on 10 Mbps Ethernet network Green flicker Activity on 100 Mbps Ethernet network Specifications ...

Страница 8: ...y suggestions on how to improve this document complete the How Are We Doing form at http literature rockwellautomation com idc groups literature documents du ra du002_ en e pdf Technical Support Center Knowledgebase Articles How to Videos FAQs Chat User Forums and Product Notification Updates https rockwellautomation custhelp com Local Technical Support Phone Numbers Locate the phone number for yo...

Отзывы: