Installation Instructions

Original Instructions

FLEX 5000 EtherNet/IP Adapters with RJ45 Ports

Catalog Numbers 5094-AENTR, 5094-AENTRXT, 5094-AEN2TR, 5094-AEN2TRXT

Product Overview

The FLEX 5000™ EtherNet/IP Adapters with RJ45 Ports perform the following functions:

• Facilitate high-speed data transfer across an EtherNet/IP network between FLEX 5000 I/O modules and a Logix 5000™ controller.

• Provide system-side power to FLEX 5000 I/O modules.

• The 5094-AENTR and 5094-AENTRXT adapters support as many as 8 FLEX 5000 I/O modules.

• The 5094-AEN2TR and 5094-AEN2TRXT adapters support as many as 16 FLEX 5000 I/O modules.

The adapters are configured with the Studio 5000 Logix Designer® application. For more information on how to use FLEX 5000 EtherNet/IP 
Adapters with RJ45 Ports, including the compatible Logix 5000 controllers and Logix Designer application versions, see the publications that are 
listed in 

Additional Resources on page 15

.

Topic Page

About the Adapter

5

Before You Begin

5

Adapter Dimensions

6

Set the Network Internet Protocol (IP) Address

7

Install the Adapter onto the DIN Rail

8

Connect Power to the Adapter

9

Connect the Adapter to an EtherNet/IP Network

11

Install the End Cap

12

Power the Adapter

13

Remove or Replace the Adapter

13

Specifications

14

Additional Resources

15

Содержание 5094-AEN2TR

Страница 1: ...94 AEN2TRXT adapters support as many as 16 FLEX 5000 I O modules The adapters are configured with the Studio 5000 Logix Designer application For more information on how to use FLEX 5000 EtherNet IP Ad...

Страница 2: ...encati nella sezione Altre risorse riguardanti l installazione la configurazione ed il funzionamento dell apparecchiatura Gli utenti devono leggere e comprendere le istruzioni di installazione e cabla...

Страница 3: ...dangereux Lorsque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature...

Страница 4: ...touch connectors or pins on component boards Do not touch circuit components inside the equipment Use a static safe workstation if available Store the equipment in appropriate static safe packaging wh...

Страница 5: ...N rail Compatible zinc plated yellow chromate steel DIN rail You canuse a steel DIN rail such as the Allen Bradley 199 DR1 46277 3 EN50022 35 x 7 5 mm 1 38 x 0 30 in EtherNet IP network components You...

Страница 6: ...d adjacent equipment You can mount the DIN rail horizontally or vertically FLEX 5000 EtherNet IP Adapter with RJ45 Ports Spacing AdapterDimensions FLEX 5000 EtherNet IP Adapter with RJ45 Ports Dimensi...

Страница 7: ...onal Resources on page 15 SettheNetworkInternetProtocol IP Address FLEX 5000 EtherNet IP Adapters with RJ45 Ports ship DHCP enabled and with their rotary switches set to 999 If the network uses 192 16...

Страница 8: ...ublication ENET UM004 InstalltheAdapterontotheDINRail The adapter must be installed left most to the I O modules 1 Make sure that the DIN rail latch is in the Locked position 2 If the DIN rail latch i...

Страница 9: ...source is properly sized For example if the total module power current draw including current inrush requirements is 4 A you can use a power supply that is limited to 4 A 1 Verify that the external po...

Страница 10: ...1 mm2 14 AWG Strip 15 1 mm 0 59 0 04 in of insulation from the wires RTB Type Action Screw 1 Insert the wire into the terminal 2 Turn the screwdriver to close the terminal on the wire Torque the screw...

Страница 11: ...etwork anelectricarccanoccur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding This warning applies to conne...

Страница 12: ...damage or injury from electric shock can result 1 Make sure that the end cap is unlocked If the end cap is locked pull the tab until it clicks 2 Align the end cap with interlocking pieces on the last...

Страница 13: ...locked 6 Pull the adapter off the DIN rail 7 To replace the adapter repeat the installation steps that are described beginning at Set the Network Internet Protocol IP Address on page 7 ATTENTION Do no...

Страница 14: ...e 100 AM at 1890 MHz 10V m with 1 kHz sine wave 80 AM from 2000 2700 MHz EFT B Immunity IEC 61000 4 4 4 kV at 5 kHz on power ports 4 kV at 5 kHz on Ethernet ports Surge Transient Immunity IEC 61000 4...

Страница 15: ...0 Control Systems User Manual publication ENET UM004 Describes how to install configure and operate EtherNet IP Communication Modules in Logix 5000 Control Systems FLEX 5000 Digital I O Modules User M...

Страница 16: ...us serve your documentation needs better If you have any suggestions on how to improve this document complete the How Are We Doing form at http literature rockwellautomation com idc groups literature...

Отзывы: