Maintenance

Every Week

Chec

k

 the correct operation of the switching circuit. Also chec

k

 for 

signs of abuse or tampering. Inspect the switch casing for damage. Of 
particular importance is damage, which causes loss of sealing at the lid 
or conduit entry.

At Least Every Six Months

Isolate the power. Remove the lid. Inspect all terminals for tightness. 
Clean out any accumulation of fine dirt, and so forth. Chec

k

 for any 

sign of wear or damage, for example, rubber boot wear or contact 
oxidization, and replace if apparent. Replace cover and tighten screws 
to specified settings. Reinstate the power and chec

k

 for correct 

operation. Reapply tamper evident varnish or similar compound to 
mountings.

Repair

If there is any malfunction or damage, no attempts at repair are made. 
The unit has to be replaced before machine operation is allowed.

DO NOT DISMANTLE THE UNIT.

Precautions for Operation

Do not apply excessive shoc

k

 to the switch. Wire the switch correctly 

after reading this instruction sheet. To help ensure safety of the control 
system, connect each pair of contacts of the three-position switch 
(terminal number 1-2 and 3-4) to a discrepancy detection circuit such 
as a safety relay module (ISO 13849-1/EN 954-1).

When wiring, prevent dust, water, or oil from entering the grip switch. 
Do not tie the grip switch around the button with tape or string to 

k

eep the switch in position two. Otherwise, the original function of the 

switch is not used, which poses a great ris

k

 of danger. If used in wet 

locations, this device must be used with cable suitable for wet locations.

EU Declaration of Conformity

The Declaration of Conformity declares that the products that are 
shown in this document conform with the relevant requirements of the 
Low Voltage Directive (2014/35/EU).

These products also conform to EN 60947-5-1, EN 60947-5-8, 
GS-ET-22, UL 508, CSA C22.2 No. 14 and have Third-Party 
Approval. Conforming with the European Machinery Directive 
depends on the application of the product.

For a comprehensive certificate, visit: www.ab.com/safety.

Additional Resources

These documents contain additional information concerning related products from Rockwell Automation®.

You can view or download publications at 

http://www.rockwellautomation.com/global/literature-library/

overview.page

. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or 

Rockwell Automation sales representative.

Resource

Description

Industrial Automation Wiring and Grounding Guidelines, 
publication 

1770-4.1

 

Provides general guidelines for installing a 
Rockwell Automation industrial system.

Product Certifications website, 

http://www.rockwellautomation.com/global/certification
/overview.page

Provides declarations of conformity, 
certificates, and other certification details.

Отзывы: