Allen-Bradley 2711P-RDT12H Скачать руководство пользователя страница 13

Rockwell Automation Publication 2711P-IN026H-EN-P - May 2018

13

High-bright Display Modules

Logic Module Compatibility

The high-bright display module is only compatible with the following DC logic modules.

PanelView Plus, PanelView Plus CE, and PanelView Plus 6 Logic Modules

The high-bright display module is not compatible with AC logic modules catalog number 
2711P-RPxAx.

External Power Supply For Nonisolated DC Terminals

Use a single, 24V DC power supply, such as catalog number 2711P-RSACDIN, to power each 
PanelView Plus device. Using a separate, isolated and ungrounded source to power each terminal 
prevents ground loop currents from damaging the terminals.

The output on the power supply must be isolated from the input and not connected to earth/
ground.

Cat. No. 

Description

PanelView Plus 700 to 1500 Logic Modules

2711P-RP2

Logic module with 128 MB flash/128 MB RAM, DC input

PanelView Plus CE 700 to 1500 Logic Modules

2711P-RP6

PanelView Plus CE logic module with 128 MB flash/128 MB RAM, DC input

PanelView Plus 6 700 to 1500 Logic Modules

2711P-RP8D

PanelView Plus 6 logic module with 1 GB flash/512 MB RAM, DC input

2711P-RP9D

PanelView Plus 6 logic module with 1 GB flash/512 MB RAM, DC input, extended features

TIP

To identify nonisolated DC logic modules refer to the PanelView Plus Terminals User Manual, 
publication 

2711P-UM001

.

ATTENTION: 

Use a safety extra-low voltage (SELV) or protective extra-low voltage (PELV) power 

supply as required by local wiring codes for your installation. The SELV or PELV power sources 
provide protection so that under normal and single-fault conditions, the voltage between the 
conductors, and between the conductors and functional earth or protective earth does not exceed 
a safe value.

Содержание 2711P-RDT12H

Страница 1: ...Installation 4 Hazardous Locations 5 Environnements dangereux 6 Wiring and Safety Guidelines 8 About the Terminals 9 Install the Terminal 9 Logic Module Compatibility 13 External Power Supply For Non...

Страница 2: ...th respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automati...

Страница 3: ...module in a panel or enclosure Refer to the installation instructions shipped with the logic module and communication module for field installation of these components For complete information on ins...

Страница 4: ...maintain internal temperatures within specification ATTENTION This equipment is intendedfor useinaPollutionDegree 2industrial environment in overvoltage Category II applications as defined in IEC publ...

Страница 5: ...decrease the display intensity by using the screen saver with a 5 10 minute delay Avoid placing the terminal on the south north in the southern hemisphere or west side of the cabinet if possible This...

Страница 6: ...ts contenant des gaz atmosph riques inflammables moins de 135 C 275 F USBPorts The terminals contain universal serial bus USB ports that comply with hazardous location environments This section detail...

Страница 7: ...for them to remain nonincendive when used with the PanelView Plus 700 to 1500 USB port If cable capacitance and inductance are not known the following values from ANSI ISA RP 12 06 01 2003 may be use...

Страница 8: ...mendations refer to the National Electrical Code published by the National Fire Protection Association For more information refer to Wiring and Grounding Guidelines for PanelView Plus Devices Technica...

Страница 9: ...uctions shipped with each module PartsList These items are shipped with the terminals Power terminal block Mounting clips FactoryTalk View software preloaded Installation instructions and panel cutout...

Страница 10: ...outDimensions Use the full size template shipped with your terminal to mark the cutout dimensions The 1250 Touch PanelView Plus PanelView Plus CE and PanelView Plus 6 Terminals are 257 mm 10 11 in hig...

Страница 11: ...on the terminal This gasket forms a compression type seal Do not use sealing compounds 3 Place the terminal in the panel cutout 4 Slide the ends of the mounting clips into the slots on the terminal 5...

Страница 12: ...igh bright display module Depth dimensions are shown for base configured unit display module and logic module base configured unit with communication module Measurements are in mm in ATTENTION Tighten...

Страница 13: ...escription PanelView Plus 700 to 1500 Logic Modules 2711P RP2 Logic module with 128 MB flash 128 MB RAM DC input PanelView Plus CE 700 to 1500 Logic Modules 2711P RP6 PanelView Plus CE logic module wi...

Страница 14: ...DC logic modules are identified by catalog number 2711P RPxDx ATTENTION UseanSELVorPELVsupplyasrequiredbylocalwiringcodesforyourinstallation The SELV and PELV power sources provide protection so that...

Страница 15: ...llow these steps to remove the terminal block 1 Loosen the two screws that secure the terminal block ATTENTION Damage or malfunction can occur when a voltage potential exists between two separate grou...

Страница 16: ...es have these ratings 24V DC nominal 18 32V DC 70 W maximum 2 9 A at 24V DC The power supply is internally protected against reverse polarity of the DC and DC connections The input power terminal bloc...

Страница 17: ...hernetCable For PanelView Plus 700 to 1500 terminals use Belden 7921A shielded Ethernet Category 5e cable according to TIA 568 B 1 and RJ45 connector according to IEC 60603 7 for compliance with the E...

Страница 18: ...wer requirements in the Specifications table CheckStatusIndicators The terminal has two status indicators to isolate operating problems COMM indicator green for communication FAULT indicator red for h...

Страница 19: ...bright display module has a built in temperature sensor that automatically reduces the backlight intensity if the temperature inside the cabinet exceeds 55 C 131 F Indicator States if the Terminal Sto...

Страница 20: ...00 x 600 Luminance 1000 cd m2 Nits Backlight Not replaceable Touch screen Analog resistive Electrical Input voltage DC 24V DC nom 18 32V DC Power consumption DC 70 W max 2 9 A 24V DC Mechanical Dimens...

Страница 21: ...ertification 1 1 See the Product Certification link on https ab rockwellautomation com fordeclarations of conformity certificates and othercertification details 2711P RDT12H c UL us UL Listed Industri...

Страница 22: ...iew Plus CE terminalsandgivesinformationonhowtoinstall operate configure and troubleshoot these devices PanelViewPlus6TerminalsUserManual publication 2711P UM006 Provides instructions on how to instal...

Страница 23: ...Rockwell Automation Publication 2711P IN026H EN P May 2018 23 High bright Display Modules Notes...

Страница 24: ...ockwell Automation maintains current product environmental information on its website at http www rockwellautomation com rockwellautomation about us sustainability ethics product environmental complia...

Отзывы: