background image

Installation Instructions

Original Instructions

Kinetix 5100 Auxiliary Feedback Connector 
Kit 

Catalog Number 2198-AUXKIT

This kit is designed to provide wire terminations for encoder signals to the auxiliary feedback 
(AUX) connector on the Kinetix® 5100 servo drives. The feedback cable that you supply must 
meet the requirements in 

Feedback Cable Requirements on page 4

.

See the Kinetix 5100 Single-axis EtherNet/IP Servo Drives Users Manual, publication

2198-UM004

, for more information on compatible 2090-Series feedback cables and wiring this 

kit.

Prepare the Feedback Cable

To prepare your feedback cable for use with the auxiliary feedback connector kit, make sure that 
the cable shield, conductor, and strip lengths are correct for your cable. Use the following 
guidelines and diagram for the feedback cable preparation. 

• Fold the shield back on to the cable jacket and trim the shield so that no strands protrude 

past the outer shell during final assembly. Wrap the cable shield with one layer of 
conductive tape.

• Measure the conductor lengths so they are long enough to connect to the terminals. 

• Remove enough insulation from each conductor to provide the proper strip length.

• Twist and pre-solder the conductor ends. 

15…20

(0.59…0.79)

5

(0.20)

4…6

(0.16…0.24)

Dimensions are in mm (in.)

Cable Jacket

Cable Shield

Strip Length