2
Rockwell Automation Publication 2198-IN018A-EN-P - May 2019
Kinetix 5100 Auxiliary Feedback Connector Kit
Prepare Connector
To make the final assembly easier and help prevent solder drips, pre-solder the connector
contacts.
Assemble the Connector Kit
Follow these steps to assemble the connector kit.
1.
Slip 10…20 mm (0.4…0.78 in.) insulation tube over each cable conductor.
2.
Route the conductors to the proper terminals and solder in place.
, for the 10-pin terminal pinout.
Set the solder iron temperature to 390 °C (734 °F).
3.
Place the cable and the wire-mount receptacle assembly in bottom of the inner shell.
4.
Align the top inner shell snap-fits to the bottom inner shell and push together.
5.
To achieve a high-frequency bond between the shield braid and the clamp, apply the
shield clamp to the 5 mm (0.20 in.) of conductive-tape wrapped cable shield.
Tighten the clamp screws by using a Phillips screwdriver to achieve 0.34 N•m
(3.0 lb•in), maximum torque.
IMPORTANT
To help prevent connector damage, complete each solder within 3…5 seconds.
IMPORTANT
To help prevent damage, make each solder connection within 10 seconds and use
minimal force on terminals.
Bottom Inner Shell
Top Inner Shell
Snap-fit (X2)
Top Inner Shell
Wire-mount
Receptacle
Cable
Conductive
Tape
Shield Clamp
Clamp Screws (2)