background image

2

Rockwell Automation Publication 2198-IN018A-EN-P - May 2019

Kinetix 5100 Auxiliary Feedback Connector Kit 

Prepare Connector

To make the final assembly easier and help prevent solder drips, pre-solder the connector 
contacts.

Assemble the Connector Kit

Follow these steps to assemble the connector kit.

1.

Slip 10…20 mm (0.4…0.78 in.) insulation tube over each cable conductor.

2.

Route the conductors to the proper terminals and solder in place.

See 

Connector Data

 on  

page 3

, for the 10-pin terminal pinout.

Set the solder iron temperature to 390 °C (734 °F).

3.

Place the cable and the wire-mount receptacle assembly in bottom of the inner shell.

4.

Align the top inner shell snap-fits to the bottom inner shell and push together.

5.

To achieve a high-frequency bond between the shield braid and the clamp, apply the 
shield clamp to the 5 mm (0.20 in.) of conductive-tape wrapped cable shield.

Tighten the clamp screws by using a Phillips screwdriver to achieve 0.34 N•m 
(3.0 lb•in), maximum torque.

IMPORTANT

To help prevent connector damage, complete each solder within 3…5 seconds.

IMPORTANT

To help prevent damage, make each solder connection within 10 seconds and use 
minimal force on terminals.

Bottom Inner Shell

Top Inner Shell
Snap-fit (X2)

Top Inner Shell

Wire-mount
Receptacle

Cable

Conductive

Tape

Shield Clamp

Clamp Screws (2)

Отзывы: