     Micro850 48 Point Programmable Controllers

Publication 2080-IN008C-EN-P - August 2017

North American Hazardous Location Approval

The following modules are North American Hazardous Location approved: 2080-LC50-48AWB, 
2080-LC50-48QWB, 2080-LC50-48QBB, 2080-LC50-48QVB, 2080-LC50-48QWBK 

 

 

The following information applies when 
operating this equipment in hazardous 
locations:

Informations sur l’utilisation de cet 
équipement en environnements 
dangereux:

Products marked "CL I, DIV 2, GP A, B, C, D" are 
suitable for use in Class I Division 2 Groups A, B, 
C, D, Hazardous Locations and nonhazardous 
locations only. Each product is supplied with 
markings on the rating nameplate indicating the 
hazardous location temperature code. When 
combining products within a system, the most 
adverse temperature code (lowest "T" number) 
may be used to help determine the overall 
temperature code of the system. Combinations 
of equipment in your system are subject to 
investigation by the local Authority Having 
Jurisdiction at the time of installation.

Les produits marqués "CL I, DIV 2, GP A, B, C, 
D" ne conviennent qu'à une utilisation en 
environnements de Classe I Division 2 
Groupes A, B, C, D dangereux et non 
dangereux. Chaque produit est livré avec des 
marquages sur sa plaque d'identification qui 
indiquent le code de température pour les 
environnements dangereux. Lorsque plusieurs 
produits sont combinés dans un système, le 
code de température le plus défavorable (code 
de température le plus faible) peut être utilisé 
pour déterminer le code de température global 
du système. Les combinaisons d'équipements 
dans le système sont sujettes à inspection par 
les autorités locales qualifiées au moment de 
l'installation.

WARNING: EXPLOSION 
HAZARD

• Do not disconnect equipment 

unless power has been removed 
or the area is known to be 
nonhazardous. 

• Do not disconnect connections to 

this equipment unless power has 
been removed or the area is 
known to be nonhazardous. 
Secure any external connections 
that mate to this equipment by 
using screws, sliding latches, 
threaded connectors, or other 
means provided with this product.

• Substitution of any component 

may impair suitability for Class I, 
Division 2.

• If this product contains batteries, 

they must only be changed in an 
area known to be nonhazardous.

AVERTISSEMENT: RISQUE 
D’EXPLOSION

• Couper le courant ou s'assurer 

que l'environnement est classé 
non dangereux avant de 
débrancher l'équipement.

• Couper le courant ou s'assurer 

que l'environnement est classé 
non dangereux avant de 
débrancher les connecteurs. 
Fixer tous les connecteurs 
externes reliés à cet 
équipement à l'aide de vis, 
loquets coulissants, 
connecteurs filetés ou autres 
moyens fournis avec ce produit.

• La substitution de tout 

composant peut rendre cet 
équipement inadapté à une 
utilisation en environnement de 
Classe I, Division 2.

• S'assurer que l'environnement 

est classé non dangereux avant 
de changer les piles.

Содержание 2080-LC50-48AWB

Страница 1: ...em portugu s como PDF V ao endere o web que aparece acima para encontrar e fazer download da publica o IT Questa pubblicazione disponibile in Italiano in formato PDF Per scaricarla collegarsi al sito...

Страница 2: ...llation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to us...

Страница 3: ...rating of 5VA or be approved for the application if nonmetallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain addition...

Страница 4: ...sque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature global du sys...

Страница 5: ...to this module or any device on the USB network an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous...

Страница 6: ...returned to the manufacturer for repair Do not dismantle the module ATTENTION To comply with the CE Low Voltage Directive LVD this equipment must be powered from a source compliant with the following...

Страница 7: ...eful when stripping wires Wire fragments that fall into the controller could cause damage Once wiring is complete make sure the controller is free of all metal fragments Resource Description Micro830...

Страница 8: ...ntroller Overview Controller Description Description Description 1 Status indicators 9 Expansion I O slot cover 2 Optional power supply slot 10 DIN rail mounting latch 3 Plug in latch 11 Mode switch 4...

Страница 9: ...and other sources of electrical noise such as hard contact switches relays and AC motor drives For more information on proper grounding guidelines see the Industrial Automation Wiring and Grounding G...

Страница 10: ...il the controller snaps onto the DIN rail 2 Push the DIN rail latch back into the latched position Use DIN rail end anchors Allen Bradley part number 1492 EA35 or 1492 EAHJ35 for vibration or shock en...

Страница 11: ...cross the coil of an inductive device you prolong the life of the output or relay contacts You also reduce the effects of voltage transients and electrical noise from radiating into adjacent systems R...

Страница 12: ...O 09 O 07 O 10 O 11 CM8 O 12 O 14 O 13 CM9 O 15 1 2 3 4 5 6 7 8 9 10 11 12 O 05 CM5 O 06 CM6 13 14 15 16 O 17 O 16 O 19 O 18 13 14 15 16 45039 Input Terminal Block Output Terminal Block I 00 COM0 I 0...

Страница 13: ...er Capacitance and Inductance Values table Capacitance and Inductance Values Nonincendive Equipment Associated Apparatus Vmax or Ui Voc or Vt or Uo Imax or Li Isc or It or Io Ci Ccable Ca or Co Li Lca...

Страница 14: ...driver Input circuit type 120V AC 12 24V sink source standard 24V sink source high speed Output circuit type Relay 24V DC sink standard and high speed 24V DC source standard and high speed Power consu...

Страница 15: ...on Type Output to Aux and Network Inputs to Outputs Type tested for 60 s 3250V DC Output to Aux and Network Inputs to Outputs 50V continuous Reinforced Insulation Type Input to Aux and Network Type te...

Страница 16: ...2 reinforced insulation Voltage category 110V AC 12 24V sink source standard 24V sink source high speed Operating voltage range 132V 60Hz AC max 16 8 26 4V DC 65 C 149 F 16 8 30 0V DC 30 C 86 F 10 26...

Страница 17: ...rrent continuous max 2 0 A 100 mA high speed operation 1 0 A 30 C 0 3 A 65 C standard operation 1 0 A 30 C 0 3 A 65 C standard operation Surge current per point See Relay Contacts Ratings on page 17 4...

Страница 18: ...500 Hz Shock operating IEC 60068 2 27 Test Ea Unpackaged Shock 25 g Shock non operating IEC 60068 2 27 Test Ea Unpackaged Shock DIN mount 25 g PANEL mount 35 g Emissions IEC 61000 6 4 ESD immunity IE...

Страница 19: ...rs Clause 8 Zone A B European Union 2014 35 EU LVD compliant with EN 61131 2 Programmable Controllers Clause 11 European Union 2011 65 EU RoHS compliant with EN 50581 Technical documentation RCM Austr...

Страница 20: ...fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures Allen Bradley Rockwell Automation Micro800 Mi...

Отзывы: