background image

 

ALLEN

&

HEATH

                  Xone:22 service manual            AP7528_3

  

       Page - 5 - of 12

 

 

  

 Servicing Precautions – General Notes 

 

Service personnel:

   

Service work should be carried out by technically qualified service personnel only.  
Mains power is dangerous and can kill.  Do not attempt to work on a linear or switched 
mode power supply if you are not suitably qualified to do so.  Do not attempt to repair 
surface mount circuit assemblies unless you are suitably qualified and have the 
necessary facilities to do so.  Replacement circuit assemblies can be ordered. 

Service facilities:

   

Ensure a suitably sized work surface is available.  Ensure this is clear of dirt, debris and 

obstructions which may damage the equipment surfaces.  Ensure adequate lighting.  
Use the correct tools for the job and ensure they are in good working order.  Ensure all 
workshop safety requirements are adhered to. 

Service information: 

Check that you have all the information you need before starting the service job.  Refer 

to the Allen & Heath web site or contact Allen & Heath technical support for details on 
the latest information.  Full technical information can be downloaded from the web site 
Distributor Zone (password required). 

Mains power:

 

 

Connect the equipment to mains power only of the type described in the user guide and 

marked on the rear panel.  The power source must provide a good ground connection.  
Ensure you always use an isolation transformer when working on any mains power 
supply unit. 

Mains cord and fuse:

 

 

Use the correct power cord as supplied with the equipment.  Do not remove or tamper 

with the ground connection in the power cord.  Heed the Important Mains Plug Wiring 
Instructions printed in the user guide if it is necessary to rewire the mains cord.  Always 
replace the equipment mains fuse with the correct type and rating as described in the 
user guide and marked on the equipment panel. 

Opening the unit:

   

Switch off and remove the mains power cord before opening the equipment.  Ensure all 

power supply covers and safety shields are in place before applying power with the unit 
open for diagnostic fault finding. 

Closing the unit:

 

 

Before finishing, check the quality and accuracy of the service work carried out.  

Remove any dirt or debris as this may cause equipment failure in the future.  Ensure all 
assemblies, harnesses and connectors are correctly aligned and plugged in.  Ensure 
that jumper settings and control configurations are correctly set according to the 
requirements of the customer. 

Continued - 

 
 

Содержание Xone:22

Страница 1: ...vice manual AP7528_3 Page 1 of 12 ALLEN HEATH SERVICE MANUAL Copyright 2009 Allen Heath Limited All rights reserved Allen Heath Limited Kernick Industrial Estate Penryn Cornwall TR10 9LU UK http www a...

Страница 2: ...ent has been installed and operated in accordance with the instructions in this User Guide The equipment has not been subject to misuse either intended or accidental neglect or alteration other than a...

Страница 3: ...AP7528_3 Page 3 of 12 CONTENTS DEVELOPMENT CHANGES SERVICING PRECAUTIONS AND GENERAL NOTES ACCESS CHANGE PHONO INPUT TO LINE INPUT PARTS IDENTIFICATION How to order parts Exterior parts Interior part...

Страница 4: ...ELOPMENT CHANGES NOTE These changes have been implemented at the factory as part of our ongoing development policy They are not critical to the basic function of the unit It is for the owner service e...

Страница 5: ...Distributor Zone password required Mains power Connect the equipment to mains power only of the type described in the user guide and marked on the rear panel The power source must provide a good groun...

Страница 6: ...esigned flight case if you need to ship the unit To avoid injury to yourself or damage to the equipment take care when lifting moving or carrying the equipment Operation To test the console make sure...

Страница 7: ...the front panel to the chassis 4 Now carefully lift the front edge of the panel up until the PCBs clear the chassis and pull the whole assembly forward slightly until the connectors at the rear are f...

Страница 8: ...nel as outlined before 2 locate and remove the two black jumper links on the input PCBs in the location shown It is a good idea to leave the jumper links attached to one pin so that they can be refitt...

Страница 9: ...www allen heath com UK distributors asp UK parts must be ordered through an appointed A H dealer or service centre A list of UK service centres can be viewed at http www allen heath com UK service_cen...

Страница 10: ...anual AP7528_3 Page 10 of 12 AJ4346 AI8004 Mix out XLR Al2411 RCA phono AL3753 Ground Pillar AL8106 Mic XLR AL2414 Headphone Large jack AL0328 Headphone Small jack AL5323 RCA phono AL4977 Phono shorti...

Страница 11: ...ALLEN HEATH Xone 22 service manual AP7528_3 Page 11 of 12 INTERIOR PARTS Input 003 873 Master 003 874 Mic is break off Connector 003 875...

Страница 12: ...Outputs Main Mix Balanced XLR 68 ohms 4dBu 25dBu Monitor RCA 68 ohms 2dBu 18dBu Record RCA 600 ohms 10dBV 10dBV FX SND RCA 47 ohms 2dBu 18dBu Headphones 3 5mm and 1 4 TRS Jacks 1 ohm 200mW RMS into 30...