background image

4  

 

 

     

 

WZ

3

12MON 

SYS-LINK Option Fitting Instructions   AP7007 

Step 9:  

Connect the SYS-LINK power 

 

Both  option  cards  get  their  power  from  the 

c15V and -15V rails available at solder 

pads on the rear connector PCB. 
Solder  the  SYS-LINK  card  sleeved  red  and 

black wires to the connector card: red to (+15), 

black to (-15), green to ground 0V.  Check that 

the solder joints are of good quality.   

 

GREEN   

GROUND 

BLACK    

-15V 

RED  

 

=  

+15V 

 

Step 10:

   Refit the clamp bracket

 

 

The  clamp  bracket  securing  nuts 

should  be  tightened  just  enough  to  prevent 

excessive  movement  of  the  IDC  harnesses.  

Do  not  overtighten  as  this  may  cause 

damage to the harnesses.

 

Refit  the  clamp  bracket  using  the  five  M3  nuts. 

The  positions  of  the  IDC  harnesses  may  need 

adjusting  to  allow  enough  slack  on  either  side 

when the clamp is tightened. 

 

 

 

 

 

 
Step 11:

   Refit the connector panel

 

Check your work carefully and ensure that there 

is no dirt or debris inside the connector pod. 
Ensure  that  all  IDC  harnesses  are  correctly 

inserted and positioned. 
Carefully  refit  the  connector  panel  to  the 

console. Replace the ten M3x6 Pozi screws - six 

at  the  rear  of  the  connector  panel  and  two  at 

each side. 

 

 
 
 

Step 12:

   Refit the base

 

Check  that  all  harnesses  are  correctly  inserted 

and  positioned,  then  carefully  replace  the  base 

panel  and  refit  the  four  underside  base  M3x6 

Pozi screws.  Rotate the connector pod and refit 

the  three  M3x6  Torx  rear  base  fixing  screws.  

Rotate the pod again and secure it in place with 

the two M4x8 flange Pozi screws.  Refit the side 

trims if required using the one M4x10 and three 

M4x8 Pozi screws per side.

 

 

Step 12:   

Apply the panel label

 

With all panels refitted, stick on the adhesive 

label AN7066 supplied with the kit. This 

identifies the top connector as SYS-LINK OUT 

and the lower connector as SYS-LINK IN. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step 13:   

Test

 

With all panels refitted, connect to the mains 

supply.  Power on and check for correct 

operation. 

 

Step 14:   

The cable

 

A 37way male to male D-type cable is required 

to interconnect two consoles fitted with the SYS-

LINK  option.    Use  36-core  shielded  cable  with 

the  36  connections  wired  one  to  one  and  the 

screen  soldered  to  pin  19.  Maximum 

recommended length is 10 metres.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

REFIT WITH 5x M3 NUTS - DO NOT OVERTIGHTEN

USER OPTION PORT A

L

R

L

R

MONITOR

EXT MONITOR IN

USER OPTION PORT B

OUT

SYS-LINK 

IN 

 

SYS-LINK

 OUT

 

A  suitable  cable  is 

available from Allen & 
Heath: 
Part   AH4131 
37way 2.8 meters 

Отзывы: