SYS-LINK Option Fitting Instructions   AP7007 

 

 

 

 

         1 

 

 

These are the instructions for fitting the SYS-LINK Version 2 console expander option to the 

MixWizard

 

WZ

3

12MON 

consoles.  Two consoles, each with SYS-LINK V2 installed, may be linked together using a 

single 37 way cable such that one becomes a channel expander (slave) to the other (master) providing a 

total of 32 channels.  This links all the mix buses and the PFL/AFL system.  The cable is not supplied but 

may be ordered separately or sourced elsewhere.  Fitting the option requires removal of the rear connector 

cover to access the internal assemblies, installation of a circuit card assembly and ribbon harness, and 

some soldering.  This work should be carried out by technically competent personnel. 
For  information  on  how  to  use  SYS-LINK  please  refer  to  the  Applications  Note  AP7008.  Should  further 

assistance be required please contact Allen & Heath Technical Support.  

Before Starting     

Please see MOD information on last page then read these fitting instructions carefully before starting.  For 

trouble  free  installation  and  operation  heed  all  the  precautions  noted.    The  console  must  be  fully 

unplugged  and  removed  from  its  rack,  plinth  or  other  furniture  before  carrying  out  the  work.    Normal 

workshop tools are required.  These include Pozi (crosshead) and Torx (starhead) screwdrivers, and a fine 

tipped soldering iron.  Provide a suitably large, well lit work surface such as a service workshop bench.  To 

avoid  damage  to  the  cosmetics  of  the  console  ensure  that  the  work  surface  is  clean  and  clear  of 

obstructions.  Allow enough time to carry out the work properly and test the results. 

Check the Contents 

003-727-A x1  SYS-LINK IN  circuit assembly 

with power harness and fixing nuts. 
003-727-B  x1  SYS-LINK  OUT  circuit 

assembly with power harness and fixing nuts. 
003-727-C  X1  SYS-LINK  IN  SLAVE  circuit 

assembly. 
AL6098 x1  short IDC ribbon harness 
AL7005 x1  long IDC ribbon harness 
AH0014 

 WIRE 7/0.2 PVC VIOLET       

          AP7008 x1 SYS-LINK V2 Applications Note. 

IMPORTANT

:

   Any changes or modifications 

to the equipment not approved by Allen & Heath 

could  void  the  compliance  of  the  equipment.  

Whilst  we  believe  the  information  in  these 

instructions  to  be  reliable  we  do  not  assume 

responsibility  for  inaccuracies.  We  also  reserve 

the  right  to  make  changes  in  the  interest  of 

further product development. 
Copyright© 2007 Allen & Heath Limited. All rights 

reserved.         www.allen-heath.com 

 

This  work  should  be  carried  out  by 

competent technical personnel only. 

 

Disconnect the mains power cord before 

opening the unit. 

 

Take  care  not  to  damage  the  panels  or 

internal  assemblies  during  fitting.    Prevent 

loose  parts  or  dirt  from  entering  the  console 

as this may cause equipment failure. 

Fitting the SYS-LINK option cards 

 

AP7007 issue 2

    Fitting Instructions for the W3MON-SLV2 Kit

SYS-LINK IN

 

IT IS RECOMMENDED THAT THIS OPTION IS FITTED BY AN APPROVED ALLEN & HEATH SERVICE AGENT 

SYS-LINK OUT 