Servicing  

 

THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. REFER ALL SERVICING TO A 

QUALIFIED SERVICE ENGINEER, THROUGH THE APPROPRIATE ALLEN & HEATH DEALER 

 
 
Initial operational tests on the power supply can be carried out by switching the unit ON and checking the front panel neon 
indicator is illuminated.  If the neon indicator is not illuminated, check the fuses are intact in the mains plug (where fitted) and the 
unit fuseholder on the rear panel. 
 
 
 

THIS OPERATION SHOULD ONLY BE CARRIED OUT BY  TECHNICALLY COMPETENT 

PERSONNEL 

 

 
If the front panel neon indicator is illuminated but the console appears not to have any power then it may be necessary to check 
the voltages present on the output connector. Refer to the Technical Specification section in this manual for the DC output 
voltage levels. If the +16V and –16V DC supplies are not present, check the DC fuses on the front of the power supply. If the 
+48V DC supply is not present, check the internal DC fuse located on the power supply circuit board. 
 
 

 

Servicing Components 

 

ALL SERVICE AND REPAIR WORK MUST ONLY BE CARRIED BY TECHNICALLY 

COMPETENT PERSONNEL 

 

 

REPLACEMENT OF ANY COMPONENTS SHOULD BE UNDERTAKEN ONLY AFTER 

DISCONNECTING THE MAINS SUPPLY LEAD FROM THE POWER SUPPLY UNIT 

 

 
 
The RPS11 power supply unit requires no internal maintenance or regular servicing. If the RPS11 requires servicing or repair 
then refer to the service manual for the power supply or contact your Allen & Heath dealer. 
 